Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

§27-693 Minimum Section

NYC 1968 Code (Vol I) > 11 Foundations > 7 Pile Foundations-General Requirements > §27-693 Minimum Section
JUMP TO FULL CODE CHAPTER
Except as provided in article ten of this subchapter for timber piles, no tapered pile shall be less than six inches in diameter at any section, nor have less than an eight inch diameter at cutoff. The taper of any tapered section may be uniform or may occur in steps. No pile of uniform section shall have a diameter of less than eight inches, or, if not circular, a dimension of less than seven and one-half inches. Tapered shoes or points of lesser dimensions may be attached to the tips of piles.

Related Code Sections


§27-693 Foundations, Minimum Section
Except as provided in article ten of this subchapter for timber piles, no tapered pile shall be less than six inches in diameter at any section, nor ...
NYC 1968 Code (Vol I) > 11 Foundations > 7 Pile Foundations-General Requirements > §27-693 Minimum Section
2113.16.1 Masonry, Minimum Area
Round chimney flues shall have a minimum net cross-sectional area of at least 1 / 12 of the fireplace opening. Square chimney flues shall have ...
NYC Building Code 2008 > 21 Masonry > 2113 Masonry Chimneys > 2113.16 Flue Area (Masonry Fireplace) > 2113.16.1 Minimum Area
2113.16.1 Masonry, Minimum Area
Round chimney flues shall have a minimum net cross-sectional area of at least 1 / 12 of the fireplace opening. Square chimney flues shall have ...
NYC Building Code 2014 > 21 Masonry > 2113 Masonry Chimneys > 2113.16 Flue Area (Masonry Fireplace) > 2113.16.1 Minimum Area
2113.16.1 Masonry, Minimum Area
Round chimney flues shall have a minimum net cross-sectional area of not less than 1 / 12 of the fireplace opening. Square chimney flues shall have ...
NYC Building Code 2022 > 21 Masonry > 2113 Masonry Chimneys > 2113.16 Flue Area (Masonry Fireplace) > 2113.16.1 Minimum Area
2109.7.2.2 Masonry, Steel Connectors
Walls shall be anchored by steel connectors having a minimum section of 1 / 4 inch (6.4 mm) by 1 1 / 2 inches (38 mm), with ends bent up at least ...
NYC Building Code 2008 > 21 Masonry > 2109 Empirical Design of Masonry > 2109.7 Anchorage > 2109.7.2 Intersecting Walls > 2109.7.2.2 Steel Connectors
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING