• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

21.3.5.1 Minimum Requirement

Fire Code 2018 of West Virginia > 21 Airports and Heliports > 21.3 Rooftop Heliport Construction and Protection > 21.3.5 Portable Fire Extinguishers > 21.3.5.1 Minimum Requirement
JUMP TO FULL CODE CHAPTER
At least one portable fire extinguisher as specified in Table 21.3.5.1 shall be provided for each takeoff and landing area, parking area, and fuel storage area. [418:9.2]
Table 21.3.5.1 Minimum Ratings of Portable Fire Extinguishers for Heliport Categories
Heliport Category Helicopter Overall Length* Minimum Rating
H-1 Less than 50 ft (15.2 m) 4-A:80-B
H-2 50 ft (15.2 m) up to but not including 80 ft (24.4 m) 10-A:120-B
H-3 80 ft (24.4 m) up to but not including 120 ft (36.6 m) 30-A:240-B
*Helicopter length, including the tail boom and the rotors.
[418: Table 9.2]

Related Code Sections


1001.2 Means of Egress, Minimum Requirements
It shall be unlawful to alter a building or structure in a manner that will reduce the number of exits or the minimum width or required capacity ...
Building Code 2015 of West Virginia > 10 Means of Egress > 1001 Administration > 1001.2 Minimum Requirements
1012.7.1 Change of Occupancy, Minimum Requirements
Vertical shafts shall be designed to meet the International Building Code requirements for atriums or the requirements of this section ...
Existing Building Code 2015 of West Virginia > 10 Change of Occupancy > 1012 Change of Occupancy Classification > 1012.7 Enclosure of Vertical Shafts > 1012.7.1 Minimum Requirements
(1) General, Minimum Required
At least one entrance of sufficient area shall be provided to give access to and egress from working space about electrical equipment ...
National Electrical Code 2017 of West Virginia > 1 General > 110 Requirements for Electrical Installations > 110.26 Spaces About Electrical Equipment > (C) Entrance to and Egress From Working Space > (1) Minimum Required
1105.1 Additions, Minimum Requirements
of, primary function shall comply with the requirements of Sections 705, 806 and 906, as applicable ...
Existing Building Code 2015 of West Virginia > 11 Additions > 1105 Accessibility > 1105.1 Minimum Requirements
1106.1 Additions, Minimum Requirements
Additions to existing buildings shall conform to the energy requirements of the International Energy Conservation Code or International ...
Existing Building Code 2015 of West Virginia > 11 Additions > 1106 Energy Conservation > 1106.1 Minimum Requirements
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING