The means of egress width shall not be less than required by this section. The total width of means of egress in inches (mm) shall not be less than the total occupant load served by the means of egress multiplied by 0.3 inch (7.62 mm) per occupant for stairways and by 0.2 inch (5.08 mm) per occupant for other egress components. The width shall not be less than specified elsewhere in this code. Multiple means of egress shall be sized such that the loss of any one means of egress shall not reduce the available capacity to less than 50 percent of the required capacity. The maximum capacity required from any story of a building shall be maintained to the termination of the means of egress.
Exception: Means of egress complying with Section 1028.
Upcodes Diagrams

Related Code Sections

1005.1 Means of Egress, Minimum Required Egress Width
The means of egress width shall not be less than required by this section. The total width of means of egress in inches (mm) shall not be less than ...
1005.1 Means of Egress, Minimum Required Egress Width
The means of egress width shall not be less than required by this section. The total width of means of egress in inches (mm) shall not be less than ...
4604.7 Construction Requirements for Existing Buildings, Minimum Required Egress Width
The means of egress width shall not be less than as required by the code under which constructed but not less than as required by this section. The ...
1028.2 Means of Egress, Exit Discharge Width or Capacity
The minimum width or required capacity of the exit discharge shall be not less than the minimum width or required capacity of the exits being served ...
1028.2 Means of Egress, Exit Discharge Width or Capacity
The minimum width or required capacity of the exit discharge shall be not less than the minimum width or required capacity of the exits being served ...