• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1910.252(c)(2)(ii) Minimum Rate

OSHA 1910 General Industry > Q Welding, Cutting, and Brazing > 1910.252 General Requirements > 1910.252(c) Health Protection and Ventilation > 1910.252(c)(2) Ventilation for General Welding and Cutting > 1910.252(c)(2)(ii) Minimum Rate
JUMP TO FULL CODE CHAPTER
Such ventilation shall be at the minimum rate of 2,000 cubic feet (57 m(3)) per minute per welder, except where local exhaust hoods and booths as per paragraph (c)(3) of this section, or airline respirators approved by the U.S. Bureau of Mines for such purposes are provided. Natural ventilation is considered sufficient for welding or cutting operations where the restrictions in paragraph (c)(2)(i) of this section are not present.

Related Code Sections


1910.252(c)(2)(ii) Welding, Cutting, and Brazing, Minimum Rate
Such ventilation shall be at the minimum rate of 2,000 cubic feet (57 m(3)) per minute per welder, except where local exhaust hoods and booths as per ...
OSHA 1910 General Industry > Q Welding, Cutting, and Brazing > 1910.252 General Requirements > 1910.252(c) Health Protection and Ventilation > 1910.252(c)(2) Ventilation for General Welding and Cutting > 1910.252(c)(2)(ii) Minimum Rate
1910.110(d)(14)(i) Hazardous Materials,
Each bulk plant shall be provided with at least one approved portable fire extinguisher having a minimum rating of 12-B, C ...
OSHA 1910 General Industry > H Hazardous Materials > 1910.110 Storage and Handling of Liquefied Petroleum Gases > 1910.110(d) > 1910.110(d)(14) Fire Protection > 1910.110(d)(14)(i)
1910.27(b)(2)(vii) Walking-Working Surfaces,
All components of each rope descent system, except seat boards, are capable of sustaining a minimum rated load of 5,000 pounds (22.2 kN). Seat boards ...
OSHA 1910 General Industry > D Walking-Working Surfaces > 1910.27 Scaffolds and Rope Descent Systems > 1910.27(b) Rope Descent Systems > 1910.27(b)(2) Use of Rope Descent Systems > 1910.27(b)(2)(vii)
1910.430(h)(2) Commercial Diving Operations,
Surface-supplied air masks and helmets shall have a minimum ventilation rate capability of 4.5 acfm at any depth at which they are operated ...
OSHA 1910 General Industry > T Commercial Diving Operations > 1910.430 Equipment > 1910.430(h) Masks and Helmets > 1910.430(h)(2)
1910.269(l)(8)(v)(D) Special Industries,
The protection for the employee's head may consist of head protection meeting ยง 1910.135 and a faceshield with a minimum arc rating of 8 cal/cm 2 ...
OSHA 1910 General Industry > R Special Industries > 1910.269 Electric Power Generation, Transmission, and Distribution > 1910.269(l) Working on or Near Exposed Energized Parts > 1910.269(l)(8) Protection From Flames and Electric Arcs > 1910.269(l)(8)(v) > 1910.269(l)(8)(v)(D)
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING