1609.6.2.2.1 Minimum Pressures
JUMP TO FULL CODE CHAPTER
The positive design wind pressures, pnet, from Section 1609.6.2.2 shall not be less than + 20 psf (1.44 kN/m2), and the negative design wind pressures, pnet, from Section 1609.6.2.2 shall not be less than — 20 psf (-1.44 kN/m2).
Related Code Sections
1609.6.2.1.1 Structural Design, Minimum Pressures
The load effects of the design wind pressures from Section 1609.6.2.1 shall not be less than assuming the pressures, p s , for Zones A, B, C ...
NYC Building Code 2008 > 16 Structural Design > 1609 Wind Loads > 1609.6 Simplified Wind Load Methods > 1609.6.2 Simplified Design Procedure-I (For Low-Rise Buildings) > 1609.6.2.1 Main Wind Force-Resisting System > 1609.6.2.1.1 Minimum Pressures
1609.6.2.1.1 Structural Design, Minimum Pressures
The load effects of the design wind pressures from Section 1609.6.2.1 shall not be less than assuming the pressures, p s , for Zones A, B, C and D ...
NYC Building Code 2014 > 16 Structural Design > 1609 Wind Loads > 1609.6 Simplified Wind Load Methods > 1609.6.2 Simplified Design Procedure I (For Low-Rise Buildings) > 1609.6.2.1 Main Wind Force-Resisting System > 1609.6.2.1.1 Minimum Pressures
513.6.1 Exhaust Systems, Minimum Pressure Difference
The minimum pressure difference across a smoke barrier shall be 0.05-inch water Gage (12.4 Pa) in fully sprinklered buildings. In buildings ...
NYC Mechanical Code 2014 > 5 Exhaust Systems > 513 Smoke Control Systems > 513.6 Pressurization Method > 513.6.1 Minimum Pressure Difference
513.6.1 Exhaust Systems, Minimum Pressure Difference
The minimum pressure difference across a smoke barrier shall be 0.05-inch water Gage (12.4 Pa) in fully sprinklered buildings. In ...
NYC Mechanical Code 2008 > 5 Exhaust Systems > 513 Smoke Control Systems > 513.6 Pressurization Method > 513.6.1 Minimum Pressure Difference
909.6.1 Fire Protection Systems, Minimum Pressure Difference
The minimum pressure difference across a smoke barrier shall be 0.05-inch water gage (0.0 124 kPa) in fully sprinklered buildings. In buildings ...
NYC Building Code 2014 > 9 Fire Protection Systems > 909 Smoke Control Systems > 909.6 Pressurization Method > 909.6.1 Minimum Pressure Difference