• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1205.2.1 Minimum Opening

NYC Building Code 2014 > 12 Interior Environment > 1205 Lighting > 1205.2 Natural Light > 1205.2.1 Minimum Opening
JUMP TO FULL CODE CHAPTER
The minimum net glazed area shall not be less than 10 percent of the floor area of the room served. Every opening providing required natural light shall be at least 12 square feet (1.1 m2) of glazed area.

Related Code Sections


1203.4.1.1.1 Interior Environment, Minimum Opening
The minimum openable area to the outdoors shall be 4 percent of the floor area of the occupiable space being ventilated ...
NYC Building Code 2008 > 12 Interior Environment > 1203 Ventilation > 1203.4 Natural Ventilation > 1203.4.1 Ventilation Area Required > 1203.4.1.1 Occupiable Spaces > 1203.4.1.1.1 Minimum Opening
1203.4.1.1.1 Interior Environment, Minimum Opening
The minimum openable area to the outdoors shall be 4 percent of the floor area of the occupiable space being ventilated ...
NYC Building Code 2014 > 12 Interior Environment > 1203 Ventilation > 1203.4 Natural Ventilation > 1203.4.1 Ventilation Area Required > 1203.4.1.1 Occupiable Spaces > 1203.4.1.1.1 Minimum Opening
1203.4.1.4.1 Interior Environment, Minimum Opening
The minimum openable area to the outdoors shall be 5 percent of the floor area of the space being ventilated. Every window or other opening providing ...
NYC Building Code 2014 > 12 Interior Environment > 1203 Ventilation > 1203.4 Natural Ventilation > 1203.4.1 Ventilation Area Required > 1203.4.1.4 Kitchenettes in R and I-1 Occupancies > 1203.4.1.4.1 Minimum Opening
1203.5.1.1.1 Interior Environment, Minimum Opening
The minimum openable area to the outdoors shall be 4 percent of the floor area of the occupiable space being ventilated ...
NYC Building Code 2022 > 12 Interior Environment > 1203 Ventilation > 1203.5 Natural Ventilation > 1203.5.1 Ventilation Area Required > 1203.5.1.1 Occupiable Spaces > 1203.5.1.1.1 Minimum Opening
1203.5.1.2.1 Interior Environment, Minimum Opening
The minimum openable area to the outdoors shall be 5 percent of the floor area of the habitable space being ventilated. Every opening providing ...
NYC Building Code 2022 > 12 Interior Environment > 1203 Ventilation > 1203.5 Natural Ventilation > 1203.5.1 Ventilation Area Required > 1203.5.1.2 Habitable Spaces > 1203.5.1.2.1 Minimum Opening
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING