• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1018.1 Minimum Number of Exits

NYC Building Code 2008 > 10 Means of Egress > 1018 Number of Exits and Continuity > 1018.1 Minimum Number of Exits
JUMP TO FULL CODE CHAPTER
All rooms and spaces within each story shall be provided with and have access to the minimum number of approved independent exits as required by Table 1018.1 based on the occupant load of such story, except as modified in Section 1018.2. For the purposes of this chapter, occupied roofs shall be provided with exits as required for stories. The required number of exits from any story, basement or individual space shall be maintained until arrival at grade or the public way.
  Exception: Unless otherwise required by other provisions of this chapter, the number of exits from ground floors discharging at grade directly to the exterior shall be determined in accordance with Table 1014.1.

TABLE 1018.1
MINIMUM NUMBER OF EXITS FOR OCCUPANT LOAD
OCCUPANT LOAD MINIMUM NUMBER OF EXITS
1-500 2
H-4, H-5 1
More than 1,000 4

1018.1.1 Open Parking Garages

Parking garages shall not have less than two exits from each parking tier. An unenclosed vehicle ramp constructed in accordance with Section 1010.2 may serve as one of the required exits when provided with pedestrian facilities along the ramp.
  Exception: Where vehicles are mechanically parked, only one exit is required but such exit shall not be a vehicle ramp.

1018.1.2 Open or Enclosed Parking Garages

In open or enclosed parking garages three stories or less in height and serving not more than one level below grade, ramps with a maximum slope of one unit vertical in seven units horizontal may serve as secondary exits.

Related Code Sections


1018.1 Means of Egress, Minimum Number of Exits
All rooms and spaces within each story shall be provided with and have access to the minimum number of approved independent exits as required ...
NYC Building Code 2008 > 10 Means of Egress > 1018 Number of Exits and Continuity > 1018.1 Minimum Number of Exits
1006.3.1 Means of Egress, Egress Based on Occupant Load
Each story or occupied roof designed for human occupancy or use shall have the minimum number of exits, or access to exits, as specified in Table ...
NYC Building Code 2022 > 10 Means of Egress > 1006 Number of Exits and Exit Access Doorways > 1006.3 Egress From Stories or Occupied Roofs > 1006.3.1 Egress Based on Occupant Load
1021.1 Means of Egress, Exits From Stories
All spaces within each story shall have access to the minimum number of approved independent exits as specified in Table 1021.1 based ...
NYC Building Code 2014 > 10 Means of Egress > 1021 Number of Exits and Continuity > 1021.1 Exits From Stories
403.5.2 Special Detailed Requirements Based on Use and Occupancy, Additional Exit Stairway
of Sections 1011 and 1023 shall be provided in addition to the minimum number of exits required by Section 1006.3 The total width of any combination ...
NYC Building Code 2022 > 4 Special Detailed Requirements Based on Use and Occupancy > 403 High-Rise Buildings > 403.5 Means of Egress and Evacuation > 403.5.2 Additional Exit Stairway
403.5.2 Special Detailed Requirements Based on Use and Occupancy, Additional Exit Stairway
of Sections 1009 and 1022 shall be provided in addition to the minimum number of exits required by Section 1021.1. The total width of any combination ...
NYC Building Code 2014 > 4 Special Detailed Requirements Based on Use and Occupancy > 403 High-Rise Buildings > 403.5 Means of Egress and Evacuation > 403.5.2 Additional Exit Stairway
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING