918.2 Minimum Duct Sizes
JUMP TO FULL CODE CHAPTER
The minimum unobstructed total area of the outdoor and return air ducts or openings to a forced-air warm-air furnace shall be not less than 2 square inches per 1,000 Btu/h (4402 mm2/kW) output rating capacity of the furnace and not less than that specified in the furnace manufacturer's installation instructions. The minimum unobstructed total area of supply ducts from a forced-air warm-air furnace shall not be less than 2 square inches for each 1,000 Btu/h (4402 mm2/kW) output rating capacity of the furnace and not less than that specified in the furnace manufacturer's installation instructions.
Exception: The total area of the supply air ducts and outdoor and return air ducts shall not be required to be larger than the minimum size required by the furnace manufacturer's installation instructions.
Related Code Sections
918.2 Specific Appliances, Fireplaces and Solid Fuel-Burning Equipment, Minimum Duct Sizes
The minimum unobstructed total area of the outdoor and return air ducts or openings to a forced-air warm-air furnace shall be not less than 2 square ...
Mechanical Code 2009 of Pennsylvania > 9 Specific Appliances, Fireplaces and Solid Fuel-Burning Equipment > 918 Forced-Air Warm-Air Furnaces > 918.2 Minimum Duct Sizes
603.4 Duct Systems, Metallic Ducts
THICKNESSES FOR SINGLE DWELLING UNITS
DUCT SIZE
GALVANIZED
ALUMINUM MINIMUM THICKNESS (in.)
Minimum thickness ...
Mechanical Code 2009 of Pennsylvania > 6 Duct Systems > 603 Duct Construction and Installation > 603.4 Metallic Ducts
504.6.1 Exhaust Systems, Material and Size
Exhaust ducts shall have a smooth interior finish and shall be constructed of metal a minimum 0.016 inch (0.4 mm) thick. The exhaust duct size shall ...
Mechanical Code 2009 of Pennsylvania > 5 Exhaust Systems > 504 Clothes Dryer Exhaust > 504.6 Domestic Clothes Dryer Ducts > 504.6.1 Material and Size
504.8.1 Exhaust Systems, Material and Size
Exhaust ducts shall have a smooth interior finish and shall be constructed of metal a minimum 0.016 inch (0.4 mm) thick. The exhaust duct size shall ...
Mechanical Code 2015 of Pennsylvania > 5 Exhaust Systems > 504 Clothes Dryer Exhaust > 504.8 Domestic Clothes Dryer Ducts > 504.8.1 Material and Size
614.6.1 Specific Appliances, Fireplaces and Solid Fuel-Burning Equipment, Material and Size
Exhaust ducts shall have a smooth interior finish and shall be constructed of metal a minimum 0.016 inch (0.4 mm) thick. The exhaust duct size shall ...
Fuel Gas Code 2009 of Pennsylvania > 6 Specific Appliances, Fireplaces and Solid Fuel-Burning Equipment > 614 (IFGC) Clothes Dryer Exhaust > 614.6 Domestic Clothes Dryer Exhaust Ducts > 614.6.1 Material and Size