• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

918.2 Minimum Duct Sizes

Mechanical Code 2009 of Pennsylvania > 9 Specific Appliances, Fireplaces and Solid Fuel-Burning Equipment > 918 Forced-Air Warm-Air Furnaces > 918.2 Minimum Duct Sizes
JUMP TO FULL CODE CHAPTER

The minimum unobstructed total area of the outdoor and return air ducts or openings to a forced-air warm-air furnace shall be not less than 2 square inches per 1,000 Btu/h (4402 mm2/kW) output rating capacity of the furnace and not less than that specified in the furnace manufacturer's installation instructions. The minimum unobstructed total area of supply ducts from a forced-air warm-air furnace shall not be less than 2 square inches for each 1,000 Btu/h (4402 mm2/kW) output rating capacity of the furnace and not less than that specified in the furnace manufacturer's installation instructions.

Exception: The total area of the supply air ducts and outdoor and return air ducts shall not be required to be larger than the minimum size required by the furnace manufacturer's installation instructions.

Related Code Sections


918.2 Specific Appliances, Fireplaces and Solid Fuel-Burning Equipment, Minimum Duct Sizes
The minimum unobstructed total area of the outdoor and return air ducts or openings to a forced-air warm-air furnace shall be not less than 2 square ...
Mechanical Code 2009 of Pennsylvania > 9 Specific Appliances, Fireplaces and Solid Fuel-Burning Equipment > 918 Forced-Air Warm-Air Furnaces > 918.2 Minimum Duct Sizes
603.4 Duct Systems, Metallic Ducts
THICKNESSES FOR SINGLE DWELLING UNITS DUCT SIZE GALVANIZED ALUMINUM MINIMUM THICKNESS (in.) Minimum thickness ...
Mechanical Code 2009 of Pennsylvania > 6 Duct Systems > 603 Duct Construction and Installation > 603.4 Metallic Ducts
504.6.1 Exhaust Systems, Material and Size
Exhaust ducts shall have a smooth interior finish and shall be constructed of metal a minimum 0.016 inch (0.4 mm) thick. The exhaust duct size shall ...
Mechanical Code 2009 of Pennsylvania > 5 Exhaust Systems > 504 Clothes Dryer Exhaust > 504.6 Domestic Clothes Dryer Ducts > 504.6.1 Material and Size
504.8.1 Exhaust Systems, Material and Size
Exhaust ducts shall have a smooth interior finish and shall be constructed of metal a minimum 0.016 inch (0.4 mm) thick. The exhaust duct size shall ...
Mechanical Code 2015 of Pennsylvania > 5 Exhaust Systems > 504 Clothes Dryer Exhaust > 504.8 Domestic Clothes Dryer Ducts > 504.8.1 Material and Size
614.6.1 Specific Appliances, Fireplaces and Solid Fuel-Burning Equipment, Material and Size
Exhaust ducts shall have a smooth interior finish and shall be constructed of metal a minimum 0.016 inch (0.4 mm) thick. The exhaust duct size shall ...
Fuel Gas Code 2009 of Pennsylvania > 6 Specific Appliances, Fireplaces and Solid Fuel-Burning Equipment > 614 (IFGC) Clothes Dryer Exhaust > 614.6 Domestic Clothes Dryer Exhaust Ducts > 614.6.1 Material and Size
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE