• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

[BS] A110.1 Minimum Design Lateral Forces

Los Angeles Existing Building Code > A Guidelines for the Seismic Retrofit of Existing Buildings > A110 General Procedure > A110.1 Minimum Design Lateral Forces
JUMP TO FULL CODE CHAPTER

Buildings shall be analyzed to resist minimum lateral forces assumed to act nonconcurrently in the direction of each of the main axes of the structure in accordance with the following:

(Equation A1-7)

Related Code Sections


A110.1 Guidelines for the Seismic Retrofit of Existing Buildings, Minimum Design Lateral Forces
Buildings shall be analyzed to resist minimum lateral forces assumed to act nonconcurrently in the direction of each of the main axes ...
Los Angeles Existing Building Code > A Guidelines for the Seismic Retrofit of Existing Buildings > A110 General Procedure > A110.1 Minimum Design Lateral Forces
A110.1 Guidelines for the Seismic Retrofit of Existing Buildings, Minimum Design Lateral Forces
Buildings shall be analyzed to resist minimum lateral forces assumed to act nonconcurrently in the direction of each of the main axes ...
Los Angeles Existing Building Code > A Guidelines for the Seismic Retrofit of Existing Buildings > A110 General Procedure > A110.1 Minimum Design Lateral Forces
1607.13.3 Structural Design, Lateral Force
The lateral force on crane runway beams with electrically powered trolleys shall be calculated as 20 percent of the sum of the rated capacity ...
Los Angeles Building Code > 16 Structural Design > 1607 Live Loads > 1607.13 Crane Loads > 1607.13.3 Lateral Force
1607.14.3 Structural Design, Lateral Force
The lateral force on crane runway beams with electrically powered trolleys shall be calculated as 20 percent of the sum of the rated capacity ...
Los Angeles Building Code > 16 Structural Design > 1607 Live Loads > 1607.14 Crane Loads > 1607.14.3 Lateral Force
1607A.13.3 Structural Design, Lateral Force
The lateral force on crane runway beams with electrically powered trolleys shall be calculated as 20 percent of the sum of the rated capacity ...
Los Angeles Building Code > 16A Structural Design > 1607A Live Loads > 1607A.13 Crane Loads > 1607A.13.3 Lateral Force
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE