722.2.4.2 Minimum Cover for R/C Columns
JUMP TO FULL CODE CHAPTER
The minimum thickness of concrete cover to the main longitudinal reinforcement in columns, regardless of the type of aggregate used in the concrete and the specified compressive strength of concrete, f 'c, shall not be less than 1 inch (25 mm) times the number of hours of required fire resistance or 2 inches (51 mm), whichever is less.
Related Code Sections
722.2.4.2 Fire and Smoke Protection Features, Minimum Cover for R/C Columns
The minimum thickness of concrete cover to the main longitudinal reinforcement in columns, regardless of the type of aggregate used in the concrete ...
DC Building Code 2017 > 7 Fire and Smoke Protection Features > 722 Calculated Fire Resistance > 722.2 Concrete Assemblies > 722.2.4 Concrete Columns > 722.2.4.2 Minimum Cover for R/C Columns
722.2.4.2 Fire and Smoke Protection Features, Minimum Cover for R/C Columns
The minimum thickness of concrete cover to the main longitudinal reinforcement in columns, regardless of the type of aggregate used in the concrete ...
DC Building Code 2013 > 7 Fire and Smoke Protection Features > 722 Calculated Fire Resistance > 722.2 Concrete Assemblies > 722.2.4 Concrete Columns > 722.2.4.2 Minimum Cover for R/C Columns
722.2.4 Fire and Smoke Protection Features, Concrete Columns
). The minimum thickness of concrete cover to the main longitudinal reinforcement in columns ...
DC Building Code 2017 > 7 Fire and Smoke Protection Features > 722 Calculated Fire Resistance > 722.2 Concrete Assemblies > 722.2.4 Concrete Columns
722.5.1 Fire and Smoke Protection Features, Structural Steel Columns
) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN NORMAL-WEIGHT CONCRETE a [FIGURE 722.5.1(6)(c)]
STRUCTURAL SHAPE
FIRE-RESISTANCE RATING ...
DC Building Code 2013 > 7 Fire and Smoke Protection Features > 722 Calculated Fire Resistance > 722.5 Steel Assemblies > 722.5.1 Structural Steel Columns
722.5.1 Fire and Smoke Protection Features, Structural Steel Columns
shall be fabricated from 0.0239-inch minimum thickness galvanized or stainless steel. For 4-hour fire-resistance ratings , the column covers shall ...
DC Building Code 2017 > 7 Fire and Smoke Protection Features > 722 Calculated Fire Resistance > 722.5 Steel Assemblies > 722.5.1 Structural Steel Columns