722.3.2.4 Minimum Concrete Masonry Fire-Resistance Rating
Go To Full Code Chapter
Where the finish applied to a concrete masonry wall contributes to its fire-resistance rating, the masonry alone shall provide not less than one-half the total required fire-resistance rating.