• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1926.1410(c) Minimum Clearance Distance

OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1410 Power Line Safety (All Voltages)--Equipment Operations Closer Than the Table A Zone > 1926.1410(c) Minimum Clearance Distance
JUMP TO FULL CODE CHAPTER

1926.1410(c)(1)

The power line owner/operator or registered professional engineer who is a qualified person with respect to electrical power transmission and distribution determines the minimum clearance distance that must be maintained to prevent electrical contact in light of the on-site conditions. The factors that must be considered in making this determination include, but are not limited to: Conditions affecting atmospheric conductivity; time necessary to bring the equipment, load line, and load (including rigging and lifting accessories) to a complete stop; wind conditions; degree of sway in the power line; lighting conditions, and other conditions affecting the ability to prevent electrical contact.

1926.1410(c)(2)

Paragraph (c)(1) of this section does not apply to work covered by Subpart V of this part; instead, for such work, the minimum approach distances established by the employer under § 1926.960(c)(1)(i) apply.

Related Code Sections


1926.1410(c) Cranes & Derricks in Construction, Minimum Clearance Distance
and distribution determines the minimum clearance distance that must be maintained to prevent electrical contact in light of the on-site conditions. The factors ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1410 Power Line Safety (All Voltages)--Equipment Operations Closer Than the Table A Zone > 1926.1410(c) Minimum Clearance Distance
1926.1407(a)(3) Cranes & Derricks in Construction, Option (3)--Table a Clearance
Determine the line's voltage and the minimum clearance distance permitted under Table A (see § 1926.1408 ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1407 Power Line Safety (Up to 350 KV)--Assembly and Disassembly > 1926.1407(a) > 1926.1407(a)(3) Option (3)--Table a Clearance
1926.1411(b)(2) Cranes & Derricks in Construction,
The clearances specified in Table T of this section are maintained. Table T-Minimum Clearance Distances While Traveling With No ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1411 Power Line Safety-While Traveling Under or Near Power Lines With No Load > 1926.1411(b) The Employer Must Ensure That: > 1926.1411(b)(2)
1926.1411(b) Cranes & Derricks in Construction, The Employer Must Ensure That:
Table T-Minimum Clearance Distances While Traveling With No Load Voltage (nominal, kV, alternating current) While traveling-minimum ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1411 Power Line Safety-While Traveling Under or Near Power Lines With No Load > 1926.1411(b) The Employer Must Ensure That:
1926.1408(d)(2) Cranes & Derricks in Construction, Exceptions
, at true vertical, would be more than 20 feet below the plane of the power line or more than the Table A of this section minimum clearance distance ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1408 Power Line Safety (Up to 350 KV)--Equipment Operations > 1926.1408(d) Operations Below Power Lines > 1926.1408(d)(2) Exceptions
Help Contact Us Privacy Terms
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE