1926.1410(c) Minimum Clearance Distance
JUMP TO FULL CODE CHAPTER
The power line owner/operator or registered professional engineer who is a qualified person with respect to electrical power transmission and distribution determines the minimum clearance distance that must be maintained to prevent electrical contact in light of the on-site conditions. The factors that must be considered in making this determination include, but are not limited to: Conditions affecting atmospheric conductivity; time necessary to bring the equipment, load line, and load (including rigging and lifting accessories) to a complete stop; wind conditions; degree of sway in the power line; lighting conditions, and other conditions affecting the ability to prevent electrical contact.
Paragraph (c)(1) of this section does not apply to work covered by Subpart V of this part; instead, for such work, the minimum approach distances established by the employer under § 1926.960(c)(1)(i) apply.
Related Code Sections
1926.1410(c) Cranes & Derricks in Construction, Minimum Clearance Distance
and distribution determines the minimum clearance distance that must be maintained to prevent electrical contact in light of the on-site conditions. The factors ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1410 Power Line Safety (All Voltages)--Equipment Operations Closer Than the Table A Zone > 1926.1410(c) Minimum Clearance Distance
1926.1407(a)(3) Cranes & Derricks in Construction, Option (3)--Table a Clearance
Determine the line's voltage and the minimum clearance distance permitted under Table A (see § 1926.1408 ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1407 Power Line Safety (Up to 350 KV)--Assembly and Disassembly > 1926.1407(a) > 1926.1407(a)(3) Option (3)--Table a Clearance
1926.1411(b)(2) Cranes & Derricks in Construction,
The clearances specified in Table T of this section are maintained.
Table T-Minimum Clearance Distances While Traveling With No ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1411 Power Line Safety-While Traveling Under or Near Power Lines With No Load > 1926.1411(b) The Employer Must Ensure That: > 1926.1411(b)(2)
1926.1411(b) Cranes & Derricks in Construction, The Employer Must Ensure That:
Table T-Minimum Clearance Distances While Traveling With No Load
Voltage (nominal, kV, alternating current)
While traveling-minimum ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1411 Power Line Safety-While Traveling Under or Near Power Lines With No Load > 1926.1411(b) The Employer Must Ensure That:
1926.1408(d)(2) Cranes & Derricks in Construction, Exceptions
, at true vertical, would be more than 20 feet below the plane of the power line or more than the Table A of this section minimum clearance distance ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1408 Power Line Safety (Up to 350 KV)--Equipment Operations > 1926.1408(d) Operations Below Power Lines > 1926.1408(d)(2) Exceptions