R602.12.6.3 Methods PFH and PFG
JUMP TO FULL CODE CHAPTER
Braced wall panels constructed as Method PFH and PFG shall be permitted when bracing units are constructed using wood structural panels. Each PFH panel shall equal one bracing unit and each PFG panel shall be equal to 0.75 bracing units.
Related Code Sections
R602.12.6.3 Wall Construction, Methods PFH and PFG
Braced wall panels constructed as Method PFH and PFG shall be permitted when bracing units are constructed using wood structural panels. Each PFH ...
Minnesota Residential Code 2015 > 6 Wall Construction > R602 Wood Wall Framing > R602.12 Simplified Wall Bracing > R602.12.6 Narrow Panels > R602.12.6.3 Methods PFH and PFG
R602.12.6.3 Wall Construction, Methods ABW, PFH and PFG
Braced wall panels constructed as Method ABW, PFH and PFG shall be permitted where bracing units are constructed using wood structural panels applied ...
2020 Minnesota Residential Code > 6 Wall Construction > R602 Wood Wall Framing > R602.12 Simplified Wall Bracing > R602.12.6 Narrow Panels > R602.12.6.3 Methods ABW, PFH and PFG
R602.10.6.3 Wall Construction, Method PFG: Portal Frame at Garage Door Openings in Seismic Design Categories A, B and C
Where supporting a roof or one story and a roof, a Method PFG braced wall panel constructed in accordance with Figure R602.10.6.3 shall ...
2020 Minnesota Residential Code > 6 Wall Construction > R602 Wood Wall Framing > R602.10 Wall Bracing > R602.10.6 Construction of Methods ABW, PFH, PFG, CS-PF and BV-WSP > R602.10.6.3 Method PFG: Portal Frame at Garage Door Openings in Seismic Design Categories A, B and C
R602.10.6.3 Wall Construction, Method PFG: Portal Frame at Garage Door Openings in Seismic Design Categories A, B and C
Where supporting a roof or one story and a roof, a Method PFG braced wall panel constructed in accordance with Figure R602.10.6.3 shall ...
Minnesota Residential Code 2015 > 6 Wall Construction > R602 Wood Wall Framing > R602.10 Wall Bracing > R602.10.6 Construction of Methods ABW, PFH, PFG, CS-PF and BV-WSP > R602.10.6.3 Method PFG: Portal Frame at Garage Door Openings in Seismic Design Categories A, B and C
R602.10.6.1 Wall Construction, Method ABW: Alternate Braced Wall Panels
Method ABW braced wall panel s shall be constructed in accordance with Figure R602.10.6.1. The hold-down force shall be in accordance with Table ...
2020 Minnesota Residential Code > 6 Wall Construction > R602 Wood Wall Framing > R602.10 Wall Bracing > R602.10.6 Construction of Methods ABW, PFH, PFG, CS-PF and BV-WSP > R602.10.6.1 Method ABW: Alternate Braced Wall Panels