[BS] C104.3.2 Method #1: Face-to-Edge or Face-to-Face Method
Go To Full Code Chapter
Retrofit studs shall be installed immediately adjacent to existing gable end wall studs as indicated in Figure C104.3(a). The retrofit studs shall overlap the edge or side of the existing stud by not less than 11/4 inches (32 mm). Fasteners shall be installed as specified in Section C104.3.1.