1910.184(g) Metal Mesh Slings
JUMP TO FULL CODE CHAPTER
Each metal mesh sling shall have permanently affixed to it a durable marking that states the rated capacity for vertical basket hitch and choker hitch loadings.
Handles shall have a rated capacity at least equal to the metal fabric and exhibit no deformation after proof testing.
The fabric and handles shall be joined so that:
The rated capacity of the sling is not reduced.
Sharp edges will not damage the fabric.
The load is evenly distributed across the width of the fabric.
Coatings which diminish the rated capacity of a sling shall not be applied.
All new and repaired metal mesh slings, including handles, shall not be used unless proof tested by the manufacturer or equivalent entity at a minimum of 11/2 times their rated capacity. Elastomer impregnated slings shall be proof tested before coating.
Metal mesh slings which are not impregnated with elastomers may be used in a temperature range from minus 20 °F to plus 550 °F without decreasing the working load limit. Metal mesh slings impregnated with polyvinyl chloride or neoprene may be used only in a temperature range from zero degrees to plus 200 °F. For operations outside these temperature ranges or for metal mesh slings impregnated with other materials, the sling manufacturer's recommendations shall be followed.
Metal mesh slings which are repaired shall not be used unless repaired by a metal mesh sling manufacturer or an equivalent entity.
Once repaired, each sling shall be permanently marked or tagged, or a written record maintained, to indicate the date and nature of the repairs and the person or organization that performed the repairs. Records of repairs shall be made available for examination.
Metal mesh slings shall be immediately removed from service if any of the following conditions are present:
A broken weld or broken brazed joint along the sling edge.
Lack of flexibility due to distortion of the fabric.
Distortion of the female handle so that the depth of the slot is increased more than 10 per cent.
Distortion of either handle so that the width of the eye is decreased more than 10 per cent.
A 15 percent reduction of the original cross sectional area of metal at any point around the handle eye.
Distortion of either handle out of its plane.
Reduction in wire diameter of 25 per cent due to abrasion or 15 per cent due to corrosion.
Related Code Sections
1910.184(g) Materials Handling and Storage, Metal Mesh Slings
Each metal mesh sling shall have permanently affixed to it a durable marking that states the rated capacity for vertical basket hitch and choker ...
OSHA 1910 General Industry > N Materials Handling and Storage > 1910.184 Slings > 1910.184(g) Metal Mesh Slings
1910.184(g)(2) Materials Handling and Storage, Handles
Handles shall have a rated capacity at least equal to the metal fabric and exhibit no deformation after proof testing ...
OSHA 1910 General Industry > N Materials Handling and Storage > 1910.184 Slings > 1910.184(g) Metal Mesh Slings > 1910.184(g)(2) Handles
1910.184(g)(3) Materials Handling and Storage, Attachments of Handles to Fabric
that: The rated capacity of the sling is not reduced. Sharp ...
OSHA 1910 General Industry > N Materials Handling and Storage > 1910.184 Slings > 1910.184(g) Metal Mesh Slings > 1910.184(g)(3) Attachments of Handles to Fabric
1910.184(g)(6) Materials Handling and Storage, [Reserved]
OSHA 1910 General Industry > N Materials Handling and Storage > 1910.184 Slings > 1910.184(g) Metal Mesh Slings > 1910.184(g)(6) [Reserved]
1910.184(g)(9) Materials Handling and Storage, Removal From Service
Metal mesh slings shall be immediately removed from service if any of the following conditions are present ...
OSHA 1910 General Industry > N Materials Handling and Storage > 1910.184 Slings > 1910.184(g) Metal Mesh Slings > 1910.184(g)(9) Removal From Service