E3906.3 Metal Boxes and Conduit Bodies
JUMP TO FULL CODE CHAPTER
Where raceway or cable is installed with metal boxes, or conduit bodies, the raceway or cable shall be secured to such boxes and conduit bodies. [314.17(B)]
Related Code Sections
E3906.3 Power and Lighting Distribution, Metal Boxes and Conduit Bodies
Where raceway or cable is installed with metal boxes, or conduit bodies, the raceway or cable shall be secured to such boxes and conduit bodies ...
2015 Virginia Residential Code > 39 Power and Lighting Distribution > E3906 Installation of Boxes, Conduit Bodies and Fittings > E3906.3 Metal Boxes and Conduit Bodies
E3906.3 Power and Lighting Distribution, Metal Boxes and Conduit Bodies
Where raceway or cable is installed with metal boxes, or conduit bodies, the raceway or cable shall be secured to such boxes and conduit bodies ...
2012 Virginia Residential Code > 39 Power and Lighting Distribution > E3906 Installation of Boxes, Conduit Bodies and Fittings > E3906.3 Metal Boxes and Conduit Bodies
E3906.8.5 Power and Lighting Distribution, Raceway Supported Enclosures, With Devices or Luminaire
) of the enclosure. [314.23(F)]
Exceptions:
Rigid metal or intermediate metal conduit shall be permitted to support a conduit body of any size ...
2015 Virginia Residential Code > 39 Power and Lighting Distribution > E3906 Installation of Boxes, Conduit Bodies and Fittings > E3906.8 Supports > E3906.8.5 Raceway Supported Enclosures, With Devices or Luminaire
E3906.8 Power and Lighting Distribution, Supports
polyvinyl chloride nonmetallic conduit or electrical metallic tubing shall be permitted to support a conduit body of any size, provided that the conduit ...
2012 Virginia Residential Code > 39 Power and Lighting Distribution > E3906 Installation of Boxes, Conduit Bodies and Fittings > E3906.8 Supports
E3905.2 Power and Lighting Distribution, Metal Boxes
Metal boxes shall be grounded. (314.4) ...
2015 Virginia Residential Code > 39 Power and Lighting Distribution > E3905 Boxes, Conduit Bodies and Fittings > E3905.2 Metal Boxes