// CODE SNIPPET
AS106.9.2 Mesh Attachment
JUMP TO FULL CODE CHAPTER
Mesh shall be attached
with staples to top plates or roof-bearing elements and to
sill plates in accordance with all of the following:
- Staples. Staples shall be pneumatically driven, stainless steel or electro-galvanized, 16 gage with 11/2-inch (38 mm) legs, 7/16-inch (11.1 mm) crown; or manually driven, galvanized, 15 gage with 1-inch (25 mm) legs. Other staples shall be permitted to be used as designed by a registered design professional. Staples into preservative-treated wood shall be stainless steel.
- Staple orientation. Staples shall be firmly driven diagonally across mesh intersections at the required spacing.
- Staple spacing. Staples shall be spaced not more than 4 inches (102 mm) on center, except where a lesser spacing is required by Table AS106.13(1) or Section AS106.14, as applicable.
Related Code Sections
AS106.9.2 Strawbale Construction, Mesh Attachment
Mesh shall be attached
with staples to top plates or roof-bearing elements and to
sill plates in accordance with all of the following:
Staples ...
2015 Michigan Residential Code > S Strawbale Construction > AS106 Strawbale Walls-Structural > AS106.9 Mesh > AS106.9.2 Mesh Attachment
AS105.7 Strawbale Construction, Inspections
, as part of and in accordance with
Section R109.1.1.
Mesh placement and attachment, where mesh is
required by this appendix.
Pins , where required ...
2015 Michigan Residential Code > S Strawbale Construction > AS105 Strawbale Walls-General > AS105.7 Inspections
AS107.1.2 Strawbale Construction, Two-Hour Rated Cement Plastered Wall
1 1 / 2 -inch (38 mm) by 17-gage galvanized woven
wire mesh shall be attached to wood members with
1 1 / 2 -inch (38 mm) staples at 6 inches (152 mm ...
2015 Michigan Residential Code > S Strawbale Construction > AS107 Fire Resistance > AS107.1 Fire-Resistance Rating > AS107.1.2 Two-Hour Rated Cement Plastered Wall
1405.7 Exterior Walls, Stone Veneer
studs spaced not more than 16
inches (406 mm) on center. On studs, the mesh shall be
attached with 2-inch-long (51 mm) corrosion-resistant
steel wire ...
2015 Michigan Building Code > 14 Exterior Walls > 1405 Installation of Wall Coverings > 1405.7 Stone Veneer
R703.8.4.2 Wall Covering, Grout Fill
with a wire mesh and
approved water-resistive barrier or an approved waterresistive
barrier-backed reinforcement attached directly
to the studs ...
2015 Michigan Residential Code > 7 Wall Covering > R703 Exterior Covering > R703.8 Anchored Stone and Masonry Veneer, General > R703.8.4 Anchorage > R703.8.4.2 Grout Fill