• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

AS106.9.2 Mesh Attachment

2015 Michigan Residential Code > S Strawbale Construction > AS106 Strawbale Walls-Structural > AS106.9 Mesh > AS106.9.2 Mesh Attachment
JUMP TO FULL CODE CHAPTER
Mesh shall be attached with staples to top plates or roof-bearing elements and to sill plates in accordance with all of the following:
  1. Staples. Staples shall be pneumatically driven, stainless steel or electro-galvanized, 16 gage with 11/2-inch (38 mm) legs, 7/16-inch (11.1 mm) crown; or manually driven, galvanized, 15 gage with 1-inch (25 mm) legs. Other staples shall be permitted to be used as designed by a registered design professional. Staples into preservative-treated wood shall be stainless steel.
  2. Staple orientation. Staples shall be firmly driven diagonally across mesh intersections at the required spacing.
  3. Staple spacing. Staples shall be spaced not more than 4 inches (102 mm) on center, except where a lesser spacing is required by Table AS106.13(1) or Section AS106.14, as applicable.

Related Code Sections


AS106.9.2 Strawbale Construction, Mesh Attachment
Mesh shall be attached with staples to top plates or roof-bearing elements and to sill plates in accordance with all of the following: Staples ...
2015 Michigan Residential Code > S Strawbale Construction > AS106 Strawbale Walls-Structural > AS106.9 Mesh > AS106.9.2 Mesh Attachment
AS105.7 Strawbale Construction, Inspections
, as part of and in accordance with Section R109.1.1. Mesh placement and attachment, where mesh is required by this appendix. Pins , where required ...
2015 Michigan Residential Code > S Strawbale Construction > AS105 Strawbale Walls-General > AS105.7 Inspections
AS107.1.2 Strawbale Construction, Two-Hour Rated Cement Plastered Wall
1 1 / 2 -inch (38 mm) by 17-gage galvanized woven wire mesh shall be attached to wood members with 1 1 / 2 -inch (38 mm) staples at 6 inches (152 mm ...
2015 Michigan Residential Code > S Strawbale Construction > AS107 Fire Resistance > AS107.1 Fire-Resistance Rating > AS107.1.2 Two-Hour Rated Cement Plastered Wall
1405.7 Exterior Walls, Stone Veneer
studs spaced not more than 16 inches (406 mm) on center. On studs, the mesh shall be attached with 2-inch-long (51 mm) corrosion-resistant steel wire ...
2015 Michigan Building Code > 14 Exterior Walls > 1405 Installation of Wall Coverings > 1405.7 Stone Veneer
R703.8.4.2 Wall Covering, Grout Fill
with a wire mesh and approved water-resistive barrier or an approved waterresistive barrier-backed reinforcement attached directly to the studs ...
2015 Michigan Residential Code > 7 Wall Covering > R703 Exterior Covering > R703.8 Anchored Stone and Masonry Veneer, General > R703.8.4 Anchorage > R703.8.4.2 Grout Fill
Help Contact Us Privacy Terms
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE