• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

714.2.1.1 Membrane Protection

2010 Building Code of NY > 7 Fire-Resistance-Rated Construction > 714 Fire-Resistance Rating of Structural Members > 714.2 Protection of Structural Members > 714.2.1 Individual Protection > 714.2.1.1 Membrane Protection
JUMP TO FULL CODE CHAPTER
King studs and boundary elements that are integral elements in load-bearing walls of light-framed construction shall be permitted to have required fire-resistance ratings provided by the membrane protection provided for the load-bearing wall.

Related Code Sections


714.2.1.1 Fire-Resistance-Rated Construction, Membrane Protection
fire-resistance ratings provided by the membrane protection provided for the load-bearing wall ...
2010 Building Code of NY > 7 Fire-Resistance-Rated Construction > 714 Fire-Resistance Rating of Structural Members > 714.2 Protection of Structural Members > 714.2.1 Individual Protection > 714.2.1.1 Membrane Protection
704.4 Fire and Smoke Protection Features, Protection of Secondary Members
Horizontal assemblies are permitted to be protected with a membrane or ceiling where the membrane or ceiling provides the required fire-resistance rating ...
Building Code 2015 of New York State > 7 Fire and Smoke Protection Features > 704 Fire-Resistance Rating of Structural Members > 704.4 Protection of Secondary Members
704.4 Fire and Smoke Protection Features, Protection of Secondary Members
required fire-resistance ratings provided by the membrane protection provided for the wall ...
2020 Building Code of New York State > 7 Fire and Smoke Protection Features > 704 Fire-Resistance Rating of Structural Members > 704.4 Protection of Secondary Members
703.1 Fire and Smoke Protection Features, Maintaining Protection
Materials and firestop systems used to protect membrane and through penetrations in fire-resistance-rated construction and construction installed ...
2020 Fire Code of NYS > 7 Fire and Smoke Protection Features > 703 Penetrations > 703.1 Maintaining Protection
704.4.2 Fire and Smoke Protection Features, Horizontal Assemblies
Horizontal assemblies are permitted to be protected with a membrane or ceiling where the membrane or ceiling provides the required fire-resistance ...
2020 Building Code of New York State > 7 Fire and Smoke Protection Features > 704 Fire-Resistance Rating of Structural Members > 704.4 Protection of Secondary Members > 704.4.2 Horizontal Assemblies
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING