• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1226.4.13.2 Medication Station

Los Angeles Building Code > 12 Interior Environment > 1226 [OSHPD 3] Clinics > 1226.4 General Construction > 1226.4.13 Support Areas for Examination and Treatment Rooms > 1226.4.13.2 Medication Station
JUMP TO FULL CODE CHAPTER

Provision shall be made for distribution of medications. This shall be done from a medicine preparation room or a self-contained medicine dispensing unit.

1226.4.13.2.1 Medicine Preparation Room or Area

When provided, the entry of the medicine preparation room or area shall be under the visual control of the staff. This may be a part of the administrative center or nurse station and shall include all of the following:

  1. Work counter
  2. Sink
  3. Lockable refrigerator
  4. Immediate access to handwashing station
  5. Locked storage for biologicals and drugs

When a medicine preparation room or area is to be used to store self-contained medicine dispensing units, the room shall be designed with adequate space to prepare medicines with the self-contained medicine-dispensing units present.

1226.4.13.2.2 Self-Contained Medicine-Dispensing Unit

When provided, the location of a self-contained medicine-dispensing unit shall be permitted in the clean workroom or at the administrative center or nurses' station, provided there is adequate security for medications and adequate lighting to easily identify drugs. Immediate access to a handwashing station shall be provided.

Related Code Sections


1224.14.2.8 Interior Environment, Medication Station
Medication station shall be provided in accordance with Section 1224.4.4.4 ...
Los Angeles Building Code > 12 Interior Environment > 1224 [OSHPD 1] Hospitals > 1224.14 Nursing Service Space > 1224.14.2 Service Areas > 1224.14.2.8 Medication Station
1226.11.2.2 Interior Environment, Medication Station
Refer to Section 1226.4.13.2 ...
Los Angeles Building Code > 12 Interior Environment > 1226 [OSHPD 3] Clinics > 1226.11 Alternative Birthing Clinics > 1226.11.2 Support Areas for Birthing Services > 1226.11.2.2 Medication Station
1226.4.13.2 Interior Environment, Medication Station
workroom or at the administrative center or nurses' station, provided there is adequate security for medications and adequate lighting to easily identify ...
Los Angeles Building Code > 12 Interior Environment > 1226 [OSHPD 3] Clinics > 1226.4 General Construction > 1226.4.13 Support Areas for Examination and Treatment Rooms > 1226.4.13.2 Medication Station
1226.5.11.6.2 Interior Environment, Medication Station
Refer to Section 1226.4.13.2 ...
Los Angeles Building Code > 12 Interior Environment > 1226 [OSHPD 3] Clinics > 1226.5 Outpatient Clinical Services of a Hospital > 1226.5.11 Gastrointestinal Endoscopy > 1226.5.11.6 Support Areas for Outpatient Gastrointestinal Endoscopy > 1226.5.11.6.2 Medication Station
1226.5.5.1.6 Interior Environment, Medication Station
Provision shall be made for locked storage of medications and drugs. Refer to Section 1226.4.13.2 ...
Los Angeles Building Code > 12 Interior Environment > 1226 [OSHPD 3] Clinics > 1226.5 Outpatient Clinical Services of a Hospital > 1226.5.5 Radiological/Imaging Service Space > 1226.5.5.1 Support Spaces for Radiological/Imaging Services > 1226.5.5.1.6 Medication Station
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE