• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1910.1025(k) Medical Removal Protection -

OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1025 Lead > 1910.1025(k) Medical Removal Protection -
JUMP TO FULL CODE CHAPTER

1910.1025(k)(1) Temporary Medical Removal and Return of an Employee -

1910.1025(k)(1)(i) Temporary Removal Due to Elevated Blood Lead Levels -

1910.1025(k)(1)(i)(A)

The employer shall remove an employee from work having an exposure to lead at or above the action level on each occasion that a periodic and a follow-up blood sampling test conducted pursuant to this section indicate that the employee's blood lead level is at or above 60 µg/100 g of whole blood; and,

1910.1025(k)(1)(i)(B)

The employer shall remove an employee from work having an exposure to lead at or above the action level on each occasion that the average of the last three blood sampling tests conducted pursuant to this section (or the average of all blood sampling tests conducted over the previous six (6) months, whichever is longer) indicates that the employee's blood lead level is at or above 50 [mu]g/100 g of whole blood; provided, however, that an employee need not be removed if the last blood sampling test indicates a blood lead level below 40 [mu]g/100 g of whole blood.

1910.1025(k)(1)(iii) Return of the Employee to Former Job Status

1910.1025(k)(1)(iii)(A) The Employer Shall Return an Employee to His or Her Former Job Status:

1910.1025(k)(1)(iii)(A)(1)

For an employee removed due to a blood lead level at or above 60 [mu]g/100 g, or due to an average blood lead level at or above 50 [mu]g/100 g, when two consecutive blood sampling tests indicate that the employee's blood lead level is below 40 [mu]g/100 g of whole blood;

1910.1025(k)(1)(iii)(A)(2)

For an employee removed due to a final medical determination, when a subsequent final medical determination results in a medical finding, determination, or opinion that the employee no longer has a detected medical condition which places the employee at increased risk of material impairment to health from exposure to lead.

1910.1025(k)(1)(iii)(B)

For the purposes of this section, the requirement that an employer return an employee to his or her former job status is not intended to expand upon or restrict any rights an employee has or would have had, absent temporary medical removal, to a specific job classification or position under the terms of a collective bargaining agreement.

1910.1025(k)(1)(iv)

Removal of other employee special protective measure or limitations. The employer shall remove any limitations placed on an employee or end any special protective measures provided to an employee pursuant to a final medical determination when a subsequent final medical determination indicates that the limitations or special protective measures are no longer necessary.

1910.1025(k)(1)(v)

Employer options pending a final medical determination. Where the multiple physician review mechanism, or alternate medical determination mechanism used pursuant to the medical surveillance provisions of this section, has not yet resulted in a final medical determination with respect to an employee, the employer shall act as follows:

1910.1025(k)(1)(v)(A) Removal

The employer may remove the employee from exposure to lead, provide special protective measures to the employee, or place limitations upon the employee, consistent with the medical findings, determinations, or recommendations of any of the physicians who have reviewed the employee's health status.

1910.1025(k)(1)(v)(B) Return

The employer may return the employee to his or her former job status, end any special protective measures provided to the employee, and remove any limitations placed upon the employee, consistent with the medical findings, determinations, or recommendations of any of the physicians who have reviewed the employee's health status, with two exceptions. If -

1910.1025(k)(1)(v)(B)(1)

the initial removal, special protection, or limitation of the employee resulted from a final medical determination which differed from the findings, determinations, or recommendations of the initial physician or

1910.1025(k)(1)(v)(B)(2)

The employee has been on removal status for the preceding eighteen months due to an elevated blood lead level, then the employer shall await a final medical determination.

1910.1025(k)(1)(ii)

Temporary removal due to a final medical determination.

1910.1025(k)(1)(ii)(A)

The employer shall remove an employee from work having an exposure to lead at or above the action level on each occasion that a final medical determination results in a medical finding, determination, or opinion that the employee has a detected medical condition which places the employee at increased risk of material impairment to health from exposure to lead.

1910.1025(k)(1)(ii)(B)

For the purposes of this section, the phrase "final medical determination" shall mean the outcome of the multiple physician review mechanism or alternate medical determination mechanism used pursuant to the medical surveillance provisions of this section.

1910.1025(k)(1)(ii)(C)

Where a final medical determination results in any recommended special protective measures for an employee, or limitations on an employee's exposure to lead, the employer shall implement and act consistent with the recommendation.

1910.1025(k)(2) Medical Removal Protection Benefits -

1910.1025(k)(2)(i) Provision of Medical Removal Protection Benefits

The employer shall provide to an employee up to eighteen (18) months of medical removal protection benefits on each occasion that an employee is removed from exposure to lead or otherwise limited pursuant to this section.

1910.1025(k)(2)(iii)

Follow-up medical surveillance during the period of employee removal or limitation. During the period of time that an employee is removed from normal exposure to lead or otherwise limited, the employer may condition the provision of medical removal protection benefits upon the employee's participation in follow-up medical surveillance made available pursuant to this section.

1910.1025(k)(2)(iv) Workers' Compensation Claims

If a removed employee files a claim for workers' compensation payments for a lead-related disability, then the employer shall continue to provide medical removal protection benefits pending disposition of the claim. To the extent that an award is made to the employee for earnings lost during the period of removal, the employer's medical removal protection obligation shall be reduced by such amount. The employer shall receive no credit for workers' compensation payments received by the employee for treatment related expenses.

1910.1025(k)(2)(v) Other Credits

The employer's obligation to provide medical removal protection benefits to a removed employee shall be reduced to the extent that the employee receives compensation for earnings lost during the period of removal either from a publicly or employer-funded compensation program, or receives income from employment with another employer made possible by virtue of the employee's removal.

1910.1025(k)(2)(vi)

Employees whose blood lead levels do not adequately decline within 18 months of removal. The employer shall take the following measures with respect to any employee removed from exposure to lead due to an elevated blood lead level whose blood lead level has not declined within the past eighteen (18) months of removal so that the employee has been returned to his or her former job status:

1910.1025(k)(2)(vi)(A)

The employer shall make available to the employee a medical examination pursuant to this section to obtain a final medical determination with respect to the employee;

1910.1025(k)(2)(vi)(B)

The employer shall assure that the final medical determination obtained indicates whether or not the employee may be returned to his or her former job status, and if not, what steps should be taken to protect the employee's health;

1910.1025(k)(2)(vi)(C)

Where the final medical determination has not yet been obtained, or once obtained indicates that the employee may not yet be returned to his or her former job status, the employer shall continue to provide medical removal protection benefits to the employee until either the employee is returned to former job status, or a final medical determination is made that the employee is incapable of ever safely returning to his or her former job status.

1910.1025(k)(2)(vi)(D)

Where the employer acts pursuant to a final medical determination which permits the return of the employee to his or her former job status despite what would otherwise be an unacceptable blood lead level, later questions concerning removing the employee again shall be decided by a final medical determination. The employer need not automatically remove such an employee pursuant to the blood lead level removal criteria provided by this section.

1910.1025(k)(2)(vii)

Voluntary Removal or Restriction of An Employee. Where an employer, although not required by this section to do so, removes an employee from exposure to lead or otherwise places limitations on an employee due to the effects of lead exposure on the employee's medical condition, the employer shall provide medical removal protection benefits to the employee equal to that required by paragraph (k)(2)(i) of this section.

1910.1025(k)(2)(ii) Definition of Medical Removal Protection Benefits

For the purposes of this section, the requirement that an employer provide medical removal protection benefits means that the employer shall maintain the earnings, seniority and other employment rights and benefits of an employee as though the employee had not been removed from normal exposure to lead or otherwise limited.

Related Code Sections


1910.1025(k) Toxic and Hazardous Substances, Medical Removal Protection -
protective measures provided to the employee, and remove any limitations placed upon the employee, consistent with the medical findings, determinations ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1025 Lead > 1910.1025(k) Medical Removal Protection -
1910.1050(m)(9)(v) Toxic and Hazardous Substances, Medical Removal Protection Benefits
The employer shall provide to an employee up to six (6) months of medical removal protection benefits on each occasion that an employee is removed ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1050 Methylenedianiline > 1910.1050(m) Medical Surveillance > 1910.1050(m)(9) Medical Removal > 1910.1050(m)(9)(v) Medical Removal Protection Benefits
1910.1027(l)(11) Toxic and Hazardous Substances, Medical Removal Protection (MRP):
The employer shall temporarily remove an employee from work where there is excess exposure to cadmium on each occasion that medical removal ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1027 Cadmium > 1910.1027(l) Medical Surveillance > 1910.1027(l)(11) Medical Removal Protection (MRP):
1910.1028(i)(9) Toxic and Hazardous Substances, Medical Removal Protection Benefits
The employer shall provide to an employee 6 months of medical removal protection benefits immediately following each occasion an employee is removed ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1028 Benzene > 1910.1028(i) Medical Surveillance > 1910.1028(i)(9) Medical Removal Protection Benefits
1910.1052(j)(11) Toxic and Hazardous Substances, Medical Removal Protection (MRP)
employer shall maintain in effect any job-related protective measures or limitations, other than removal, for as long as a medical determination ...
OSHA 1910 General Industry > Z Toxic and Hazardous Substances > 1910.1052 Methylene Chloride > 1910.1052(j) Medical Surveillance > 1910.1052(j)(11) Medical Removal Protection (MRP)
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING