Mechanical joint couplings for hubless pipe and fittings shall consist of an elastomeric sealing sleeve and a metallic shield that comply with CISPI 310, ASTM C1277 or ASTM C1540. The elastomeric sealing sleeve shall conform to ASTM C564 or CSA B602 and shall have a center stop. Mechanical joint couplings shall be installed in accordance with the manufacturer's instructions.

Related Code Sections

705.3.3 Sanitary Drainage, Mechanical Joint Coupling
Mechanical joint couplings for hubless pipe and fittings shall consist of an elastomeric sealing sleeve and a metallic shield that comply with CISPI ...
P3003.4.3 Sanitary Drainage, Mechanical Joint Coupling
Mechanical joint couplings for hubless pipe and fittings shall consist of an elastomeric sealing sleeve and a metallic shield that comply with CISPI ...
P3003.4.3 Sanitary Drainage, Mechanical Joint Coupling
Mechanical joint couplings for hubless pipe and fittings shall consist of an elastomeric sealing sleeve and a metallic shield that comply with CISPI ...
8.15.22* Installation Requirements, System Subdivision
Where individual floor/zone control valves are not provided, a flanged joint or mechanical coupling shall be used at the riser at each floor ...