• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1705.11.6 Mechanical and Electrical Components

Building Code 2012 of South Holland > 17 Special Inspections and Tests > 1705 Required Verification and Inspection > 1705.11 Special Inspections for Seismic Resistance > 1705.11.6 Mechanical and Electrical Components
JUMP TO FULL CODE CHAPTER
Special inspection for mechanical and electrical components shall be as follows:
  1. Periodic special inspection is required during the anchorage of electrical equipment for emergency and standby power systems in structures assigned to Seismic Design Category C, D, E or F;
  2. Periodic special inspection is required during the anchorage of other electrical equipment in structures assigned to Seismic Design Category E or F;
  3. Periodic special inspection is required during the installation and anchorage of piping systems designed to carry hazardous materials and their associated mechanical units in structures assigned to Seismic Design Category C, D, E or F;
  4. Periodic special inspection is required during the installation and anchorage of ductwork designed to carry hazardous materials in structures assigned to Seismic Design Category C, D, E or F; and
  5. Periodic special inspection is required during the installation and anchorage of vibration isolation systems in structures assigned to Seismic Design Category C, D, E or F where the construction documents require a nominal clearance of 1/4 inch (6.4 mm) or less between the equipment support frame and restraint.

Related Code Sections


1705.11.6 Special Inspections and Tests, Mechanical and Electrical Components
Special inspection for mechanical and electrical components shall be as follows: Periodic special inspection is required during the anchorage ...
Building Code 2012 of South Holland > 17 Special Inspections and Tests > 1705 Required Verification and Inspection > 1705.11 Special Inspections for Seismic Resistance > 1705.11.6 Mechanical and Electrical Components
1705.12.6 Special Inspections and Tests, Plumbing, Mechanical and Electrical Components
Periodic special inspection of plumbing, mechanical and electrical components shall be required for the following: Anchorage of electrical ...
Building Code 2018 of South Holland > 17 Special Inspections and Tests > 1705 Required Special Inspections and Tests > 1705.12 Special Inspections for Seismic Resistance > 1705.12.6 Plumbing, Mechanical and Electrical Components
1402.7 Exterior Walls, Flood Resistance for Coastal High-Hazard Areas and Coastal A Zones
For buildings in coastal high-hazard areas and coastal A zones as established in Section 1612.3, electrical, mechanical and plumbing system ...
Building Code 2018 of South Holland > 14 Exterior Walls > 1402 Performance Requirements > 1402.7 Flood Resistance for Coastal High-Hazard Areas and Coastal A Zones
1403.7 Exterior Walls, Flood Resistance for High-Velocity Wave Action Areas
For buildings in flood hazard areas subject to high-velocity wave action as established in Section 1612.3, electrical, mechanical and plumbing system ...
Building Code 2012 of South Holland > 14 Exterior Walls > 1403 Performance Requirements > 1403.7 Flood Resistance for High-Velocity Wave Action Areas
513.2 Special Occupancies, Definitions
with electrical components suitable to be moved only with mechanical aids or is provided with wheels for movement by person(s) or powered devices ...
National Electrical Code 2014 of South Holland > 5 Special Occupancies > 513 Aircraft Hangars > 513.2 Definitions
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING