• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

E4004.5 Means of Support

2012 Virginia Residential Code > 40 Devices and Luminaires > E4004 Luminaire Installation > E4004.5 Means of Support
JUMP TO FULL CODE CHAPTER
Outlet boxes or fittings installed as required by Sections E3905 and E3906 shall be permitted to support luminaires.

Related Code Sections


E4004.5 Devices and Luminaires, Means of Support
Outlet boxes or fittings installed as required by Sections E3905 and E3906 shall be permitted to support luminaires. [410.36(A)] ...
2015 Virginia Residential Code > 40 Devices and Luminaires > E4004 Luminaire Installation > E4004.5 Means of Support
E4004.5 Devices and Luminaires, Means of Support
Outlet boxes or fittings installed as required by Sections E3905 and E3906 shall be permitted to support luminaires ...
2012 Virginia Residential Code > 40 Devices and Luminaires > E4004 Luminaire Installation > E4004.5 Means of Support
E3904.3.1 Power and Lighting Distribution, Prohibited Means of Support
Cable wiring methods shall not be used as a means of support for other cables, raceways and nonelectrical equipment. [300.11(C)] ...
2015 Virginia Residential Code > 39 Power and Lighting Distribution > E3904 General Installation Requirements > E3904.3 Securing and Supporting > E3904.3.1 Prohibited Means of Support
E3904.3.1 Power and Lighting Distribution, Prohibited Means of Support
Cable wiring methods shall not be used as a means of support for other cables, raceways and nonelectrical equipment ...
2012 Virginia Residential Code > 39 Power and Lighting Distribution > E3904 General Installation Requirements > E3904.3 Securing and Supporting > E3904.3.1 Prohibited Means of Support
301.8 General Regulations, Vibration Isolation
Where means for isolation of vibration of an appliance is installed, an approved means for support and restraint of that appliance shall ...
2015 Virginia Fuel Gas Code > 3 General Regulations > 301 (IFGC) General > 301.8 Vibration Isolation
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE