1012.4.1 Means of Egress for Change to Higher Hazard Category
JUMP TO FULL CODE CHAPTER
When a change of occupancy classification is made to a higher hazard category (lower number) as shown in Table 1012.4, the means of egress shall comply with the requirements of Chapter 10 of the International Building Code.
Exceptions:
- Stairways shall be enclosed in compliance with the applicable provisions of Section 903.1.
- Existing stairways including handrails and guards complying with the requirements of Chapter 9 shall be permitted for continued use subject to approval of the code official.
- Any stairway replacing an existing stairway within a space where the pitch or slope cannot be reduced because of existing construction shall not be required to comply with the maximum riser height and minimum tread depth requirements.
- Existing corridor walls constructed on both sides of wood lath and plaster in good condition or 1/2 inch-thick (12.7 mm) gypsum wallboard shall be permitted. Such walls shall either terminate at the underside of a ceiling of equivalent construction or extend to the underside of the floor or roof next above.
- Existing corridor doorways, transoms and other corridor openings shall comply with the requirements in Sections 805.5.1, 805.5.2 and 805.5.3.
- Existing dead-end corridors shall comply with the requirements in Section 805.6.
- An existing operable window with clear opening area no less than 4 square feet (0.38 m2) and minimum opening height and width of 22 inches (559 mm) and 20 inches (508 mm), respectively, shall be accepted as an emergency escape and rescue opening.
Related Code Sections
1012.4.1 Change of Occupancy, Means of Egress for Change to Higher Hazard Category
When a change of occupancy classification is made to a higher hazard category (lower number) as shown in Table 1012.4, the means of egress shall ...
Existing Building Code 2015 of Idaho > 10 Change of Occupancy > 1012 Change of Occupancy Classification > 1012.4 Means of Egress, General > 1012.4.1 Means of Egress for Change to Higher Hazard Category
1011.4.1 Change of Occupancy, Means of Egress for Change to a Higher-Hazard Category
Where a change of occupancy classification is made to a higher-hazard category (lower number) as shown in Table 1011.4, the means of egress shall ...
Existing Building Code 2018 of Idaho > 10 Change of Occupancy > 1011 Change of Occupancy Classification > 1011.4 Means of Egress, General > 1011.4.1 Means of Egress for Change to a Higher-Hazard Category
Section 1012 Change of Occupancy, Change of Occupancy Classification
When a change of occupancy classification is made to a higher hazard category (lower number) as shown in Table 1012.4, the means of egress ...
Existing Building Code 2015 of Idaho > 10 Change of Occupancy > 1012 Change of Occupancy Classification
1011.5.1 Change of Occupancy, Height and Area for Change to a Higher-Hazard Category
Where a change of occupancy classification is made to a higher-hazard category as shown in Table 1011.5, heights and areas of buildings ...
Existing Building Code 2018 of Idaho > 10 Change of Occupancy > 1011 Change of Occupancy Classification > 1011.5 Heights and Areas > 1011.5.1 Height and Area for Change to a Higher-Hazard Category
1012.5.1 Change of Occupancy, Height and Area for Change to Higher Hazard Category
When a change of occupancy classification is made to a higher hazard category as shown in Table 1012.5, heights and areas of buildings and structures ...
Existing Building Code 2015 of Idaho > 10 Change of Occupancy > 1012 Change of Occupancy Classification > 1012.5 Heights and Areas > 1012.5.1 Height and Area for Change to Higher Hazard Category