42-223 Maximum Permitted Steady State Vibration Displacement
JUMP TO FULL CODE CHAPTER
In all Manufacturing Districts, no activity shall cause or create a steady state vibration at any point on any lot line, with a displacement in excess of the permitted steady state vibration displacement for the frequencies as set forth in the following table for the district indicated.
MAXIMUM PERMITTED STEADY STATE VIBRATION DISPLACEMENT
(in inches)
District | |||
Frequency | M1 | M2 | M3 |
10 and below | .0008 | .0020 | .0039 |
10 - 20 | .0005 | .0010 | .0022 |
20 - 30 | .0003 | .0006 | .0011 |
30 - 40 | .0002 | .0004 | .0007 |
40 - 50 | .0001 | .0003 | .0005 |
50 - 60 | .0001 | .0002 | .0004 |
60 and over | .0001 | .0001 | .0004 |
Related Code Sections
603.18 Duct Systems, Vibration Isolation Connectors
Vibration isolation connectors in duct systems shall be made of an approved flame-retardant fabric or shall consist of sleeve joints with packing ...
NYC Mechanical Code 2014 > 6 Duct Systems > 603 Duct Construction and Installation > 603.18 Vibration Isolation Connectors
603.18 Duct Systems, Vibration Isolation Connectors
Vibration isolation connectors in duct systems shall be made of an approved flame-retardant fabric or shall consist of sleeve joints with packing ...
NYC Mechanical Code 2008 > 6 Duct Systems > 603 Duct Construction and Installation > 603.18 Vibration Isolation Connectors
1305.9.7 Fuel-Oil Piping and Storage, Movement and Vibration
The piping shall be located and secured from movement so as to prevent undue stress on the piping and to isolate the piping from vibrations from any ...
NYC Mechanical Code 2014 > 13 Fuel-Oil Piping and Storage > 1305 Fuel-Oil System Installation > 1305.9 Supplemental Requirements for Piping From Transfer Pumps to Equipment or Storage Tanks Above Lowest Floor > 1305.9.7 Movement and Vibration
1305.9.7 Fuel-Oil Piping and Storage, Movement and Vibration
The piping shall be located and secured from movement so as to prevent undue stress on the piping and to isolate the piping from vibrations from any ...
NYC Mechanical Code 2008 > 13 Fuel-Oil Piping and Storage > 1305 Fuel-Oil System Installation > 1305.9 Supplemental Requirements for Piping From Transfer Pumps to Equipment or Storage Tanks Above Lowest Floor > 1305.9.7 Movement and Vibration
301.10 General Regulations, Vibration Isolation
Where vibration isolation of equipment and appliances is employed, supplemental restraint shall be used to accomplish the support and restraint ...