23-22 Maximum Number of Dwelling Units
JUMP TO FULL CODE CHAPTER
R1 R2 R3 R4 R5 R6 R7 R8 R9 R10
In all districts, as indicated, the maximum number of dwelling units shall equal the maximum residential floor area permitted on the zoning lot divided by the applicable factor in the following table. In R1 through R5 Districts, no rooming units shall be permitted and any dwelling unit shall be occupied by only one family. Fractions equal to or greater than three-quarters resulting from this calculation shall be considered to be one dwelling unit.
For the purposes of this Section, where a floor area ratio is determined pursuant to Section 23-151 (Basic regulations for R6 through R9 Districts), notwithstanding the height factor of the zoning lot, the maximum residential floor area ratio shall be 2.43 in an R6 District within 100 feet of a wide street, 3.44 in an R7 District and 6.02 in an R8 District. In an R6 District beyond 100 feet of a wide street, the maximum residential floor area ratio shall be as specified in Section 23-151, or 2.2, whichever is greater.
For affordable independent residences for seniors, there shall be no applicable dwelling unit factor.
For zoning lots with buildings containing multiple uses or multiple buildings with different uses, special provisions are set forth in Section 23-24 (Special Provisions for Buildings Containing Multiple Uses) to determine the maximum number of dwelling units permitted.
FACTOR FOR DETERMINING MAXIMUM NUMBER OF DWELLING UNITS
District | Factor for Dwelling Units |
R1-1 | 4,750 |
R1-2 | 2,850 |
R2 R2A | 1,900 |
R2X | 2,900 |
R3-1 R3-21 | 625 |
R3A | 710 |
R3-2 R4 R4-1 R4B | 870 |
R3X | 1,000 |
R4A | 1,280 |
R42 R52 R5B | 900 |
R5 R5D | 760 |
R5A | 1,560 |
R5B3 | 1,350 |
R6 R7 R8 R9 R10 | 680 |
1 for single- and two-family detached and semi-detached residences
2 for residences in a predominantly built-up area
3 for zoning lots with less than 40 feet of street frontage and existing on the effective date of establishing such districts on the zoning maps
Related Code Sections
1006.3.2.1 Means of Egress, Mixed Occupancies
not exceed one. Where dwelling units
are located on a story with other occupancies, the actual number of dwelling units divided by
four plus the ratio ...
NYC Building Code 2022 > 10 Means of Egress > 1006 Number of Exits and Exit Access Doorways > 1006.3 Egress From Stories or Occupied Roofs > 1006.3.2 Single Exits > 1006.3.2.1 Mixed Occupancies
Section 1018 Means of Egress, Number of Exits and Continuity
with a maximum slope of one unit vertical in seven units horizontal may serve as secondary exits ...
E104.2.3 Supplementary Accessibility Requirements, Dwelling Units and Sleeping Units
Where dwelling units and sleeping
units are altered or added, the requirements of Section E104.2 shall apply only to the
units being altered ...
NYC Building Code 2022 > E Supplementary Accessibility Requirements > E104 Special Occupancies > E104.2 Communication Features > E104.2.3 Dwelling Units and Sleeping Units
E104.3.3 Supplementary Accessibility Requirements, Dwelling Units and Sleeping Units
Where dwelling units and sleeping units are altered or added, the requirements of Section E104.3 shall apply only to the units being altered or added ...
NYC Building Code 2014 > E Supplementary Accessibility Requirements > E104 Special Occupancies > E104.3 Communication Features > E104.3.3 Dwelling Units and Sleeping Units
1021.2 Means of Egress, Single Exits
are met:
The building does not exceed four stories;
The building contains not more than three dwelling units per story;
The building ...
NYC Building Code 2014 > 10 Means of Egress > 1021 Number of Exits and Continuity > 1021.2 Single Exits