• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

306.6.1 Maximum Gap

Swimming Pool and Spa Code 2015 > 3 General Compliance > 306 Decks > 306.6 Gaps > 306.6.1 Maximum Gap
JUMP TO FULL CODE CHAPTER
The open gap between pool decks and adjoining decks or walkways, including joint material, shall be not greater than 3/4 inch (19.1 mm). The difference in vertical elevation between the pool deck and the adjoining sidewalk shall be not greater than 1/4 inch (6.4 mm).

Related Code Sections


306.5.1 General Compliance, Maximum Gap
The open gap between pool decks and adjoining decks or walkways, including joint material, shall be not greater than 3 / 4 inch (19.1 mm). The ...
Swimming Pool and Spa Code 2012 > 3 General Compliance > 306 Decks > 306.5 Gaps > 306.5.1 Maximum Gap
306.6.1 General Compliance, Maximum Gap
The open gap between pool decks and adjoining decks or walkways, including joint material, shall be not greater than 3 / 4 inch (19.1 mm). The ...
Swimming Pool and Spa Code 2015 > 3 General Compliance > 306 Decks > 306.6 Gaps > 306.6.1 Maximum Gap
R403.1.3.5.4 Foundations, Lap Splices
shall be in accordance with Table R608.5.4.(1) and Figure R608.5.4(1). The maximum gap between noncontact parallel bars at a lap splice shall ...
Residential Code 2015 > 4 Foundations > R403 Footings > R403.1 General > R403.1.3 Footing and Stem Wall Reinforcing in Seismic Design Categories D0, D1, and D2 > R403.1.3.5 Reinforcement > R403.1.3.5.4 Lap Splices
R403.1.3.5.4 Foundations, Lap Splices
shall be in accordance with Table R608.5.4.(1) and Figure R608.5.4(1). The maximum gap between noncontact parallel bars at a lap splice shall ...
Residential Code 2018 > 4 Foundations > R403 Footings > R403.1 General > R403.1.3 Footing and stem wall reinforcing in Seismic Design Categories D0, D1, and D2 > R403.1.3.5 Reinforcement > R403.1.3.5.4 Lap Splices
R404.1.2.3.7.5 Foundations, Lap Splices
splice shall be in accordance with Table R611.5.4.(1) and Figure R611.5.4(1). The maximum gap between noncontact parallel bars at a lap splice shall ...
Residential Code 2009 > 4 Foundations > R404 Foundation and Retaining Walls > R404.1 Concrete and Masonry Foundation Walls > R404.1.2 Concrete Foundation Walls > R404.1.2.3 Concrete, Materials for Concrete, and Forms > R404.1.2.3.7 Reinforcement > R404.1.2.3.7.5 Lap Splices
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE