• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

3303.11.1.1 Maximum Distance

NYC Building Code 2008 > 33 Safeguards During Construction or Demolition > 3303 Safeguards and Maintenance of Site > 3303.11 Maintenance of Exits During Construction or Demolition > 3303.11.1 Temporary Stairways in Unoccupied Buildings > 3303.11.1.1 Maximum Distance
JUMP TO FULL CODE CHAPTER
The maximum distance between the working deck of such a building under construction or alteration and the highest floor accessible to a temporary or permanent stair shall be no more than 40 feet or 4 floors. In concrete construction, the working deck is the floor being formed. In steel construction the working deck is the floor where the metal decking and steel components are being placed before concrete is poured.

Related Code Sections


3303.11.1.1 Safeguards During Construction or Demolition, Maximum Distance
The maximum distance between the working deck of such a building under construction or alteration and the highest floor accessible to a temporary ...
NYC Building Code 2008 > 33 Safeguards During Construction or Demolition > 3303 Safeguards and Maintenance of Site > 3303.11 Maintenance of Exits During Construction or Demolition > 3303.11.1 Temporary Stairways in Unoccupied Buildings > 3303.11.1.1 Maximum Distance
8.11.3.1* Installation Requirements, Maximum Distance Between Sprinklers
Under obstructed combustible construction, the maximum distance shall be limited to 10 ft (3 m) ...
Standard for the Installation of Sprinkler Systems 2016 of New York City > 8 Installation Requirements > 8.11 CMSA Sprinklers > 8.11.3 Sprinkler Spacing (CMSA Sprinklers) > 8.11.3.1* Maximum Distance Between Sprinklers
8.12.3.1 Installation Requirements, Maximum Distance Between Sprinklers
The maximum distance between sprinklers shall be in accordance with the following: Where the storage height is less than or equal to 25 ft (7.6 m ...
Standard for the Installation of Sprinkler Systems 2016 of New York City > 8 Installation Requirements > 8.12 Early Suppression Fast-Response Sprinklers > 8.12.3 Sprinkler Spacing (Early Suppression Fast-Response Sprinklers) > 8.12.3.1 Maximum Distance Between Sprinklers
8.5.3.1 Installation Requirements, Maximum Distance Between Sprinklers
The maximum distance permitted between sprinklers shall be based on the centerline distance between adjacent sprinklers ...
Standard for the Installation of Sprinkler Systems 2016 of New York City > 8 Installation Requirements > 8.5 Position, Location, Spacing, and Use of Sprinklers > 8.5.3 Sprinkler Spacing > 8.5.3.1 Maximum Distance Between Sprinklers
8.6.3.1 Installation Requirements, Maximum Distance Between Sprinklers
The maximum distance permitted between sprinklers shall comply with Table 8.6.2.2.1(a) through Table 8.6.2.2.1(d) ...
Standard for the Installation of Sprinkler Systems 2016 of New York City > 8 Installation Requirements > 8.6 Standard Pendent and Upright Spray Sprinklers > 8.6.3 Sprinkler Spacing (Standard Pendent and Upright Spray Sprinklers) > 8.6.3.1 Maximum Distance Between Sprinklers
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING