3303.11.1.1 Maximum Distance
JUMP TO FULL CODE CHAPTER
The maximum distance between the working deck of such a building under construction or alteration and the highest floor accessible to a temporary or permanent stair shall be no more than 40 feet or 4 floors. In concrete construction, the working deck is the floor being formed. In steel construction the working deck is the floor where the metal decking and steel components are being placed before concrete is poured.
Related Code Sections
3303.11.1.1 Safeguards During Construction or Demolition, Maximum Distance
The maximum distance between the working deck of such a building under construction or alteration and the highest floor accessible to a temporary ...
NYC Building Code 2008 > 33 Safeguards During Construction or Demolition > 3303 Safeguards and Maintenance of Site > 3303.11 Maintenance of Exits During Construction or Demolition > 3303.11.1 Temporary Stairways in Unoccupied Buildings > 3303.11.1.1 Maximum Distance
8.11.3.1* Installation Requirements, Maximum Distance Between Sprinklers
Under obstructed combustible construction, the maximum distance shall be limited to 10 ft (3 m) ...
Standard for the Installation of Sprinkler Systems 2016 of New York City > 8 Installation Requirements > 8.11 CMSA Sprinklers > 8.11.3 Sprinkler Spacing (CMSA Sprinklers) > 8.11.3.1* Maximum Distance Between Sprinklers
8.12.3.1 Installation Requirements, Maximum Distance Between Sprinklers
The maximum distance between sprinklers shall be in accordance with the following: Where the storage height is less than or equal to 25 ft (7.6 m ...
Standard for the Installation of Sprinkler Systems 2016 of New York City > 8 Installation Requirements > 8.12 Early Suppression Fast-Response Sprinklers > 8.12.3 Sprinkler Spacing (Early Suppression Fast-Response Sprinklers) > 8.12.3.1 Maximum Distance Between Sprinklers
8.5.3.1 Installation Requirements, Maximum Distance Between Sprinklers
The maximum distance permitted between sprinklers shall be based on the centerline distance between adjacent sprinklers ...
Standard for the Installation of Sprinkler Systems 2016 of New York City > 8 Installation Requirements > 8.5 Position, Location, Spacing, and Use of Sprinklers > 8.5.3 Sprinkler Spacing > 8.5.3.1 Maximum Distance Between Sprinklers
8.6.3.1 Installation Requirements, Maximum Distance Between Sprinklers
The maximum distance permitted between sprinklers shall comply with Table 8.6.2.2.1(a) through Table 8.6.2.2.1(d) ...
Standard for the Installation of Sprinkler Systems 2016 of New York City > 8 Installation Requirements > 8.6 Standard Pendent and Upright Spray Sprinklers > 8.6.3 Sprinkler Spacing (Standard Pendent and Upright Spray Sprinklers) > 8.6.3.1 Maximum Distance Between Sprinklers