306.2.2 Maximum Depth
Go To Full Code Chapter
Toe clearance shall extend 25 inches (635 mm) maximum under an element.
Related Code Sections
306.2.2 Building Blocks, Maximum Depth
Toe clearance shall extend 25 inches (635 mm) maximum under an element ...
308.2.2 Building Blocks, Obstructed High Reach
reach depth over the obstruction. The high forward reach shall be 48 inches (1220 mm) maximum where the reach depth is 20 inches (510 mm) maximum ...
809.2.2 Special Rooms, Spaces, and Elements, Turning Space
in exterior spaces 30 inches (760 mm) maximum in depth or width.
Advisory 809.2.2 Turning Space. It is generally acceptable to use required ...
610.2 Plumbing Elements and Facilities, Bathtub Seats
The top of bathtub seats shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the bathroom finish floor. The depth ...
1009.3.2 Recreation Facilities, Submerged Depth
Sloped entries shall extend to a depth of 24 inches (610 mm) minimum and 30 inches (760 mm) maximum below the stationary water level. Where landings ...