2610.4 Maximum Area of Skylight
JUMP TO FULL CODE CHAPTER
Each skylight shall have a maximum area within the curb of 100 square feet (9.3 m2).
Exception: The area limitation shall not apply where the building is equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1 or the building is equipped with smoke and heat vents in accordance with Section 910.
Related Code Sections
2610.4 Plastic, Maximum Area of Skylight
Each skylight shall have a maximum area within the curb of 100 square feet (9.3 m 2 ).
Exception: The area limitation shall not apply where ...
2015 Michigan Building Code > 26 Plastic > 2610 Light-Transmitting Plastic Skylight Glazing > 2610.4 Maximum Area of Skylight
N1102.5 [RE] Energy Efficiency, (R402.5) Maximum Fenestration U-factor and SHGC (Mandatory)
and 0.40
in Zones 6 through 8 for vertical fenestration, and 0.75 in
Zones 4 through 8 for skylights. The area-weighted average
maximum fenestration ...
2015 Michigan Residential Code > 11 [RE] Energy Efficiency > N1102 Building Thermal Envelope > N1102.5 (R402.5) Maximum Fenestration U-factor and SHGC (Mandatory)
712.1.15 Fire and Smoke Protection Features, Skylights
Skylights and other penetrations
through a fire-resistance-rated roof deck or slab are permitted
to be unprotected, provided that the structural ...
2015 Michigan Building Code > 7 Fire and Smoke Protection Features > 712 Vertical Openings > 712.1 General > 712.1.15 Skylights
Section 2405 Glass and Glazing, Sloped Glazing and Skylights
:
F g
=
Maximum load on the skylight determined from Equations 24-2 through 24-4 in Section 2404.2.
PG ...
R308.6 Building Planning, Skylights and Sloped Glazing
Skylights and sloped glazing shall comply with the following sections ...
2015 Michigan Residential Code > 3 Building Planning > R308 Glazing > R308.6 Skylights and Sloped Glazing