The aggregate area of all light-transmitting plastics shall not exceed 24 square feet (2.23 m2).
Exception: In buildings equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1, the aggregate area of light-transmitting plastics shall not exceed 100 square feet (9.29 m2), provided that all plastics are Class CC1 in accordance with Section 2606.4.

Related Code Sections

2611.2 Plastic, Maximum Area
The aggregate area of all light-transmitting plastics shall not exceed 24 square feet (2.23 m2). Exception: In buildings equipped throughout ...
2611.2 Plastic, Maximum Area
The aggregate area of all light-transmitting plastics shall not exceed 24 square feet (2.23 m2). Exception: In buildings equipped throughout ...
2610.4 Plastic, Maximum Area of Skylights
Each skylight shall have a maximum area within the curb of 100 square feet (9.3 m2). Exception: The area limitation shall not apply where ...