• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

R404.1.2.3.3 Maximum Aggregate Size

Georgia State Minimum Standard One and Two Family Dwelling Code > 4 Foundations > R404 Foundation and Retaining Walls > R404.1 Concrete and Masonry Foundation Walls > R404.1.2 Concrete Foundation Walls > R404.1.2.3 Concrete, Materials for Concrete, and Forms > R404.1.2.3.3 Maximum Aggregate Size
JUMP TO FULL CODE CHAPTER
The nominal maximum size of coarse aggregate shall not exceed one-fifth the narrowest distance between sides of forms, or three-fourths the clear spacing between reinforcing bars or between a bar and the side of the form.

Exception: When approved, these limitations shall not apply where removable forms are used and workability and methods of consolidation permit concrete to be placed without honeycombs or voids.

Related Code Sections


R404.1.2.3.3 Foundations, Maximum Aggregate Size
The nominal maximum size of coarse aggregate shall not exceed one-fifth the narrowest distance between sides of forms, or three-fourths the clear ...
Georgia State Minimum Standard One and Two Family Dwelling Code > 4 Foundations > R404 Foundation and Retaining Walls > R404.1 Concrete and Masonry Foundation Walls > R404.1.2 Concrete Foundation Walls > R404.1.2.3 Concrete, Materials for Concrete, and Forms > R404.1.2.3.3 Maximum Aggregate Size
R404.1.3.3.3 Foundations, Maximum Aggregate Size
The nominal maximum size of coarse aggregate shall not exceed one-fifth the narrowest distance between sides of forms, or three-fourths the clear ...
Georgia State Minimum Standard One and Two Family Dwelling Code > 4 Foundations > R404 Foundation and Retaining Walls > R404.1 Concrete and Masonry Foundation Walls > R404.1.3 Concrete Foundation Walls > R404.1.3.3 Concrete, Materials for Concrete, and Forms > R404.1.3.3.3 Maximum Aggregate Size
R608.5.1.3 Wall Construction, Maximum Aggregate Size
The nominal maximum size of coarse aggregate shall not exceed one-fifth the narrowest distance between sides of forms, or three-fourths the clear ...
Georgia State Minimum Standard One and Two Family Dwelling Code > 6 Wall Construction > R608 Exterior Concrete Wall Construction > R608.5 Materials > R608.5.1 Concrete and Materials for Concrete > R608.5.1.3 Maximum Aggregate Size
R611.5.1.2 Wall Construction, Maximum Aggregate Size
The nominal maximum size of coarse aggregate shall not exceed one-fifth the narrowest distance between sides of forms, or three-fourths the clear ...
Georgia State Minimum Standard One and Two Family Dwelling Code > 6 Wall Construction > R611 Exterior Concrete Wall Construction > R611.5 Materials > R611.5.1 Concrete and Materials for Concrete > R611.5.1.2 Maximum Aggregate Size
1908.10.2 Concrete, Panel Criteria
Where the maximum-size aggregate is larger than 3 / 8 inch (9.5 mm), the test panels shall have minimum dimensions of 18 inches by 18 inches (457 ...
Georgia State Minimum Standard Building Code > 19 Concrete > 1908 Shotcrete > 1908.10 Strength Tests > 1908.10.2 Panel Criteria
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE