702.6 Materials and Methods
JUMP TO FULL CODE CHAPTER
All new work shall comply with the materials and methods requirements in the Florida Building Code, Building; Florida Building Code, Energy Conservation; Florida Building Code, Mechanical; and Florida Building Code, Plumbing, as applicable, that specify material standards, detail of installation and connection, joints, penetrations, and continuity of any element, component, or system in the building.
The following sections of the Florida Building Code, Fuel Gas shall constitute the fuel gas materials and methods requirements for Level 1 alterations.
- All of Chapter 3, entitled "General Regulations," except Sections 303.7 and 306.
All of Chapter 4, entitled "Gas Piping Installations," except Sections 401.8 and 402.3.
- 2.1. Sections 401.8 and 402.3 shall apply when the work being performed increases the load on the system such that the existing pipe does not meet the size required by code. Existing systems that are modified shall not require resizing as long as the load on the system is not increased and the system length is not increased even if the altered system does not meet code minimums.
- All of Chapter 5, entitled "Chimneys and Vents."
- All of Chapter 6, entitled "Specific Appliances."
Related Code Sections
702.4 Alterations—Level 1, Materials and Methods
All new work shall comply with the materials and methods requirements in the Florida Building Code, Building , Florida Building Code, Energy ...
2014 FBC - Existing Building, 5th edition > 7 Alterations—Level 1 > 702 Building Elements and Materials > 702.4 Materials and Methods
702.6 Alterations—Level 1, Materials and Methods
All new work shall comply with the materials and methods requirements in the Florida Building Code, Building ; Florida Building Code, Energy ...
2017 FBC - Existing Building, 6th edition > 7 Alterations—Level 1 > 702 Building Elements and Materials > 702.6 Materials and Methods
702.6 Alterations — Level 1, Materials and Methods
All new work shall comply with the materials and methods requirements in the Florida Building Code, Building ; Florida Building Code, Energy ...
2020 FBC - Existing Building, 7th edition > 7 Alterations — Level 1 > 702 Building Elements and Materials > 702.6 Materials and Methods
C102 Florida Standard for Mitigation of Radon in Existing Buildings, Alternate Materials and Methods
The provisions of this standard are not intended to prevent the use of any material or method of construction not specifically prescribed ...
2017 FBC - Building, 6th edition > C Florida Standard for Mitigation of Radon in Existing Buildings > C102 Alternate Materials and Methods
C102 Florida Standard for Mitigation of Radon in Existing Buildings, Alternate Materials and Methods
The provisions of this standard are not intended to prevent the use of any material or method of construction not specifically prescribed ...
2020 FBC - Building, 7th edition > C Florida Standard for Mitigation of Radon in Existing Buildings > C1 Administration > C102 Alternate Materials and Methods