P-507.4 Material and Design
JUMP TO FULL CODE CHAPTER
The bodies of cleanout ferrules shall conform in thickness to that required for pipe and
fittings of the same metal or of nylon resin, shall extend not less than 1/8 inch and shall be provided with a raised nut
or recessed socket for removal.
Both ferrule and plug shall have American National Tapered Pipe Threads and are permitted
for repairing a cleanout, where necessary.