• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

R404.1.5.1 Masonry Wall Thickness

Los Angeles Residential Code > 4 Foundations > R404 Foundation and Retaining Walls > R404.1 Concrete and Masonry Foundation Walls > R404.1.5 Foundation Wall Thickness Based on Walls Supported > R404.1.5.1 Masonry Wall Thickness
JUMP TO FULL CODE CHAPTER
Masonry foundation walls shall be not bless than the thickness of the wall supported, except that masonry foundation walls of at least 8-inch (203 mm) nominal thickness shall be permitted under brick veneered frame walls and under 10-inch-wide (254 mm) cavity walls where the total height of the wall supported, including gables, is not more than 20 feet (6096 mm), provided the requirements of Section R404.1.1 are met.

Related Code Sections


R404.1.5.1 Foundations, Masonry Wall Thickness
Masonry foundation walls shall be not bless than the thickness of the wall supported, except that masonry foundation walls of at least 8-inch (203 mm ...
Los Angeles Residential Code > 4 Foundations > R404 Foundation and Retaining Walls > R404.1 Concrete and Masonry Foundation Walls > R404.1.5 Foundation Wall Thickness Based on Walls Supported > R404.1.5.1 Masonry Wall Thickness
R404.1.5.1 Foundations, Masonry Wall Thickness
Masonry foundation walls shall be not less than the thickness of the wall supported, except that masonry foundation walls of not less than 8-inch ...
Los Angeles Residential Code > 4 Foundations > R404 Foundation and Retaining Walls > R404.1 Concrete and Masonry Foundation Walls > R404.1.5 Foundation Wall Thickness Based on Walls Supported > R404.1.5.1 Masonry Wall Thickness
2113.10.1 Masonry, Masonry Veneer Chimneys
Where masonry is used as veneer for a framed chimney, through flashing and weep holes shall be provided as required by Chapter 14 ...
Los Angeles Building Code > 21 Masonry > 2113 Masonry Chimneys > 2113.10 Wall Thickness > 2113.10.1 Masonry Veneer Chimneys
2113.10.1 Masonry, Masonry Veneer Chimneys
Where masonry is used as veneer for a framed chimney, through flashing and weep holes shall be provided as required by Chapter 14 ...
Los Angeles Building Code > 21 Masonry > 2113 Masonry Chimneys > 2113.10 Wall Thickness > 2113.10.1 Masonry Veneer Chimneys
2113A.10.1 Masonry, Masonry Veneer Chimneys
Where masonry is used as veneer for a framed chimney, through flashing and weep holes shall be provided as required by Chapter 14 ...
Los Angeles Building Code > 21A Masonry > 2113A Masonry Chimneys > 2113A.10 Wall Thickness > 2113A.10.1 Masonry Veneer Chimneys
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE