R606.3.2 Masonry Unit Placement
JUMP TO FULL CODE CHAPTER
The mortar shall be sufficiently plastic and units shall be placed with sufficient pressure to extrude mortar from the joint and produce a tight joint. Deep furrowing of bed joints that produces voids shall not be permitted. Any units disturbed to the extent that initial bond is broken after initial placement shall be removed and relaid in fresh mortar. Surfaces to be in contact with mortar shall be clean and free of deleterious materials.
Solid masonry units shall be laid with full head and bed joints and all interior vertical joints that are designed to receive mortar shall be filled.
For hollow masonry units, head and bed joints shall be filled solidly with mortar for a distance in from the face of the unit not less than the thickness of the face shell.
Related Code Sections
R606.3.2 Wall Construction, Masonry Unit Placement
Solid masonry units shall be laid with full head ...
Residential Code 2018 of Kansas > 6 Wall Construction > R606 General Masonry Construction > R606.3 Construction Requirements > R606.3.2 Masonry Unit Placement
R607.10 Wall Construction, Placement
Glass units shall be placed so head and bed joints are filled solidly. Mortar shall not be furrowed. Head and bed joints of glass unit masonry shall ...
26.5.2 Construction Documents and Inspection, Concrete Placement and Consolidation
professional and the building official. (c) Masonry filler units that will be in contact with concrete shall be prewetted prior to placing concrete ...
Building Code Requirements for Structural Concrete of Kansas > 26 Construction Documents and Inspection > 26.5 Concrete Production and Construction > 26.5.2 Concrete Placement and Consolidation
R404.1.7 Foundations, Backfill Placement
Backfill shall not be placed against the wall until the wall has sufficient strength and has been anchored to the floor above, or has been ...
Residential Code 2018 of Kansas > 4 Foundations > R404 Foundation and Retaining Walls > R404.1 Concrete and Masonry Foundation Walls > R404.1.7 Backfill Placement
26.6.2 Construction Documents and Inspection, Placement
displacement beyond required tolerances during concrete placement. (b) Spiral units shall be continuous bar or wire placed with even spacing ...
Building Code Requirements for Structural Concrete of Kansas > 26 Construction Documents and Inspection > 26.6 Reinforcement Materials and Construction Requirements > 26.6.2 Placement