• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

R606.3.1.1 Masonry Opening Tolerances

2020 FBC - Residential, 7th edition > 6 Wall Construction > R606 General Masonry Construction > R606.3 Construction Requirements > R606.3.1 Bed and Head Joints > R606.3.1.1 Masonry Opening Tolerances
JUMP TO FULL CODE CHAPTER
Masonry rough openings may vary in the cross section dimension or elevation dimension specified on the approved plans from - 1/4 inch (6.4 mm) to + 1/2 inch (12.7 mm). For exterior window and door installation provisions, see Section R609.3.

Related Code Sections


R606.16 Wall Construction, Masonry Opening Tolerances
Masonry rough openings may vary in the cross section dimension or elevation dimension specified on the approved plans from - 1 / 4 inches (6.4 mm ...
2014 FBC - Residential, 5th edition > 6 Wall Construction > R606 General Masonry Construction > R606.16 Masonry Opening Tolerances
R606.3.1.1 Wall Construction, Masonry Opening Tolerances
Masonry rough openings may vary in the cross section dimension or elevation dimension specified on the approved plans from - 1 / 4 inch (6.4 mm ...
2020 FBC - Residential, 7th edition > 6 Wall Construction > R606 General Masonry Construction > R606.3 Construction Requirements > R606.3.1 Bed and Head Joints > R606.3.1.1 Masonry Opening Tolerances
R606.3.1.1 Wall Construction, Masonry Opening Tolerances
Masonry rough openings may vary in the cross section dimension or elevation dimension specified on the approved plans from - 1 / 4 inch (6.4 mm ...
2017 FBC - Residential, 6th edition > 6 Wall Construction > R606 General Masonry Construction > R606.3 Construction Requirements > R606.3.1 Bed and Head Joints > R606.3.1.1 Masonry Opening Tolerances
R609.9 Wall Construction, Masonry Rough Openings
Masonry rough opening dimensions shall be within the tolerances specified in Section R606.3.1.1 and, in addition, shall provide for a window ...
2020 FBC - Residential, 7th edition > 6 Wall Construction > R609 Exterior Windows and Doors > R609.9 Masonry Rough Openings
R609.9 Wall Construction, Masonry Rough Openings
Masonry rough opening dimensions shall be within the tolerances specified in Section R606.3.1.1 and, in addition, shall provide for a window ...
2017 FBC - Residential, 6th edition > 6 Wall Construction > R609 Exterior Windows and Doors > R609.9 Masonry Rough Openings
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING