2113.18 Masonry Chimney Cleanout Openings
JUMP TO FULL CODE CHAPTER
Cleanout openings shall be provided within 6 inches (152 mm) of the base of each flue within every masonry chimney. The upper edge of the cleanout shall be located not less than 6 inches (152 mm) below the lowest chimney inlet opening. The height of the opening shall be not less than 6 inches (152 mm). The cleanout shall be provided with a noncombustible cover.
Exception: Chimney flues serving masonry fireplaces, where cleaning is possible through the fireplace opening.
Related Code Sections
2113.18 Masonry, Masonry Chimney Cleanout Openings
Cleanout openings shall be provided within 6 inches (152 mm) of the base of each flue within every masonry chimney. The upper edge of the cleanout ...
Building Code 2021 of Illinois > 21 Masonry > 2113 Masonry Chimneys > 2113.18 Masonry Chimney Cleanout Openings
2113.18 Masonry, Masonry Chimney Cleanout Openings
Cleanout openings shall be provided within 6 inches (152 mm) of the base of each flue within every masonry chimney. The upper edge of the cleanout ...
Building Code 2018 of Illinois > 21 Masonry > 2113 Masonry Chimneys > 2113.18 Masonry Chimney Cleanout Openings
2111.3 Masonry, Footings and Foundations
Footings for masonry fireplaces and their chimneys shall be constructed of concrete or solid masonry not less than 12 inches (305 mm) thick ...
Building Code 2021 of Illinois > 21 Masonry > 2111 Masonry Fireplaces > 2111.3 Footings and Foundations
2111.3 Masonry, Footings and Foundations
Footings for masonry fireplaces and their chimneys shall be constructed of concrete or solid masonry not less than 12 inches (305 mm) thick and shall ...
Building Code 2018 of Illinois > 21 Masonry > 2111 Masonry Fireplaces > 2111.3 Footings and Foundations
712.1.8 Fire and Smoke Protection Features, Masonry Chimney
Approved vertical openings for masonry chimneys shall be permitted where the annular space is fireblocked at each floor level in accordance ...
Building Code 2021 of Illinois > 7 Fire and Smoke Protection Features > 712 Vertical Openings > 712.1 General > 712.1.8 Masonry Chimney