• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

Section 3106 Marquees

Building Code 2018 of Illinois > 31 Special Construction > 3106 Marquees
JUMP TO FULL CODE CHAPTER

3106.1 General

Marquees shall comply with Sections 3106.2 through 3106.5 and other applicable sections of this code.

3106.2 Thickness

The height or thickness of a marquee measured vertically from its lowest to its highest point shall be not greater than 3 feet (914 mm) where the marquee projects more than two-thirds of the distance from the lot line to the curb line, and shall be not greater than 9 feet (2743 mm) where the marquee is less than two-thirds of the distance from the lot line to the curb line.

3106.3 Roof Construction

Where the roof or any part thereof is a skylight, the skylight shall comply with the requirements of Chapter 24. Every roof and skylight of a marquee shall be sloped to downspouts that shall conduct any drainage from the marquee in such a manner so as not to spill over the sidewalk.

3106.4 Location Prohibited

Every marquee shall be so located as not to interfere with the operation of any exterior standpipe, and such that the marquee does not obstruct the clear passage of stairways or exit discharge from the building or the installation or maintenance of street lighting.

3106.5 Construction

A marquee shall be supported entirely from the building and constructed of noncombustible materials. Marquees shall be designed as required in Chapter 16. Structural members shall be protected to prevent deterioration.

Related Code Sections


Section 3106 Special Construction, Marquees
Marquees shall comply with Sections 3106.2 through 3106.5 and other applicable sections of this code ...
Building Code 2021 of Illinois > 31 Special Construction > 3106 Marquees
Section 3106 Special Construction, Marquees
Marquees shall comply with Sections 3106.2 through 3106.5 and other applicable sections of this code ...
Building Code 2018 of Illinois > 31 Special Construction > 3106 Marquees
3202.3.1 Encroachments Into the Public Right-Of-Way, Awnings, Canopies, Marquees and Signs
Awnings , canopies , marquees and signs shall be constructed so as to support applicable loads as specified in Chapter 16. Awnings , canopies ...
Building Code 2021 of Illinois > 32 Encroachments Into the Public Right-Of-Way > 3202 Encroachments > 3202.3 Encroachments 8 Feet or More Above Grade > 3202.3.1 Awnings, Canopies, Marquees and Signs
3202.3.1 Encroachments Into the Public Right-Of-Way, Awnings, Canopies, Marquees and Signs
Awnings , canopies , marquees and signs shall be constructed so as to support applicable loads as specified in Chapter 16. Awnings , canopies ...
Building Code 2018 of Illinois > 32 Encroachments Into the Public Right-Of-Way > 3202 Encroachments > 3202.3 Encroachments 8 Feet or More Above Grade > 3202.3.1 Awnings, Canopies, Marquees and Signs
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING