• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

716.3 Marking Fire-Rated Glazing Assemblies

Building Code 2015 of New York State > 7 Fire and Smoke Protection Features > 716 Opening Protectives > 716.3 Marking Fire-Rated Glazing Assemblies
JUMP TO FULL CODE CHAPTER
Fire-rated glazing assemblies shall be marked in accordance with Tables 716.3, 716.5 and 716.6.
TABLE 716.3
MARKING FIRE-RATED GLAZING ASSEMBLIES
FIRE TEST STANDARD MARKING DEFINITION OF MARKING
ASTM E119 or UL 263 W Meets wall assembly criteria.
NFPA 257 or UL 9 OH Meets fire window assembly criteria including the hose stream test.
NFPA 252 or UL 10B or UL 10C D Meets fire door assembly criteria.
H Meets fire door assembly hose stream test.
T Meets 450°F temperature rise criteria for 30 minutes
XXX The time in minutes of the fire-resistance or fire protection rating of the glazing assembly.

For SI: °C = [(°F) - 32]/1.8.

716.3.1 Fire-Rated Glazing Identification

For fire-rated glazing, the label shall bear the identification required in Tables 716.3 and 716.5. "D" indicates that the glazing is permitted to be used in fire door assemblies and that the glazing meets the fire protection requirements of NFPA 252. "H" shall indicate that the glazing meets the hose stream requirements of NFPA 252. "T" shall indicate that the glazing meets the temperature requirements of Section 716.5.5.1. The placeholder "XXX" represents the fire-rating period, in minutes.

716.3.2 Fire-Protection-Rated Glazing Identification

For fire-protection-rated glazing, the label shall bear the following identification required in Tables 716.3 and 716.6: "OH — XXX." "OH" indicates that the glazing meets both the fire protection and the hose-stream requirements of NFPA 257 or UL 9 and is permitted to be used in fire window openings. The placeholder "XXX" represents the fire-rating period, in minutes.

716.3.3 Fire-Rated Glazing That Exceeds the Code Requirements

Fire-rated glazing assemblies marked as complying with hose stream requirements (H) shall be permitted in applications that do not require compliance with hose stream requirements. Fire-rated glazing assemblies marked as complying with temperature rise requirements (T) shall be permitted in applications that do not require compliance with temperature rise requirements. Fire-rated glazing assemblies marked with ratings (XXX) that exceed the ratings required by this code shall be permitted.

Related Code Sections


716.3 Fire and Smoke Protection Features, Marking Fire-Rated Glazing Assemblies
Fire-rated glazing assemblies shall be marked in accordance with Tables 716.3, 716.5 and 716.6. TABLE 716.3 MARKING FIRE-RATED GLAZING ...
Building Code 2015 of New York State > 7 Fire and Smoke Protection Features > 716 Opening Protectives > 716.3 Marking Fire-Rated Glazing Assemblies
716.1.2.2 Fire and Smoke Protection Features, Marking Fire-Rated Glazing Assemblies
Fire-rated glazing assemblies shall be marked in accordance with Tables 716.1(1), 716.1(2) and 716.1(3 ...
2020 Building Code of New York State > 7 Fire and Smoke Protection Features > 716 Opening Protectives > 716.1 General > 716.1.2 Glazing > 716.1.2.2 Marking Fire-Rated Glazing Assemblies
716.1.2.2.2 Fire and Smoke Protection Features, Fire-Protection-Rated Glazing Identification
For fire-protection-rated glazing, the label shall bear the following identification required in Tables 716.1(1) and 716.1(3): "OH — XXX." "OH ...
2020 Building Code of New York State > 7 Fire and Smoke Protection Features > 716 Opening Protectives > 716.1 General > 716.1.2 Glazing > 716.1.2.2 Marking Fire-Rated Glazing Assemblies > 716.1.2.2.2 Fire-Protection-Rated Glazing Identification
716.1.2.2.3 Fire and Smoke Protection Features, Fire-Resistance-Rated Glazing Identification
For fire-resistance-rated glazing, the label shall bear the identification required in Section 703.6 and Table 716.1.(1) ...
2020 Building Code of New York State > 7 Fire and Smoke Protection Features > 716 Opening Protectives > 716.1 General > 716.1.2 Glazing > 716.1.2.2 Marking Fire-Rated Glazing Assemblies > 716.1.2.2.3 Fire-Resistance-Rated Glazing Identification
716.1.2 Fire and Smoke Protection Features, Glazing
). Fire-rated glazing assemblies marked as complying with hose stream requirements (H) shall be permitted in applications that do not require ...
2020 Building Code of New York State > 7 Fire and Smoke Protection Features > 716 Opening Protectives > 716.1 General > 716.1.2 Glazing
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE