// CODE SNIPPET
1926.1437(k) Manufacturer's Specifications and Limitations
JUMP TO FULL CODE CHAPTER
The employer must ensure that the barge, pontoons, vessel, or other means of flotation must be capable of withstanding imposed environmental, operational and in-transit loads when used in accordance with the manufacturer's specifications and limitations.
The employer must ensure that the manufacturer's specifications and limitations with respect to environmental, operational, and in-transit loads for a barge, pontoon, vessel, or other means of flotation are not exceeded or violated.
When the manufacturer's specifications and limitations are unavailable, the employer must ensure that the specifications and limitations established by a qualified person with respect to environmental, operational and in-transit loads for the barge, pontoons, vessel, or other means of flotation are not exceeded or violated.
Related Code Sections
1926.1437(k) Cranes & Derricks in Construction, Manufacturer's Specifications and Limitations
, operational and in-transit loads when used in accordance with the manufacturer's specifications and limitations ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1437 Floating Cranes/Derricks and Land Cranes/Derricks on Barges > 1926.1437(k) Manufacturer's Specifications and Limitations
1926.552(a)(1) Helicopters, Hoists, Elevators, and Conveyors,
The employer shall comply with the manufacturer's specifications and limitations applicable to the operation of all hoists and elevators. Where ...
OSHA 1926 Construction > N Helicopters, Hoists, Elevators, and Conveyors > 1926.552 Material Hoists, Personnel Hoists, and Elevators > 1926.552(a) General Requirements > 1926.552(a)(1)
1926.753(e)(1)(v) Steel Erection,
No crane is permitted to be used for a multiple lift where such use is contrary to the manufacturer's specifications and limitations ...
OSHA 1926 Construction > R Steel Erection > 1926.753 Hoisting and Rigging > 1926.753(e) Multiple Lift Rigging Procedure > 1926.753(e)(1) > 1926.753(e)(1)(v)
1926.652(c)(2)(iii) Excavations,
Manufacturer's specifications, recommendations, and limitations, and manufacturer's approval to deviate from the specifications, recommendations ...
OSHA 1926 Construction > P Excavations > 1926.652 Requirements for Protective Systems > 1926.652(c) Design of Support Systems, Shield Systems, and Other Protective Systems > 1926.652(c)(2) Option (2)-Designs Using Manufacturer's Tabulated Data > 1926.652(c)(2)(iii)
1926.552(a) Helicopters, Hoists, Elevators, and Conveyors, General Requirements
The employer shall comply with the manufacturer's specifications and limitations applicable to the operation of all hoists and elevators. Where ...
OSHA 1926 Construction > N Helicopters, Hoists, Elevators, and Conveyors > 1926.552 Material Hoists, Personnel Hoists, and Elevators > 1926.552(a) General Requirements