1910.263(h) Manually Fed Dough Brakes
Go To Full Code Chapter
-
1910.263(h)(1) Top-Roll Protection
The top roll shall be protected by a heavy gage metal shield extending over the roll to go within 6 inches of the hopper bottom board. The shield may be perforated to permit observation of the dough entering the rolls.
1910.263(h)(2) Emergency Stop Bar
An emergency stop bar shall be provided, and so located that the body of the operator will press against the bar if the operator slips and falls toward the rolls, or if the operator gets his hand caught in the rolls. The bar shall apply the body pressure to open positively a circuit that will deenergize the drive motor. In addition, a brake which is inherently self-engaging by requiring power or force from an external source to cause disengagement shall be activated at the same time causing the rolls to stop instantly. The emergency stop bar shall be checked for proper operation every 30 days.
Related Code Sections
1910.263(h) Special Industries, Manually Fed Dough Brakes
metal shield extending over the roll to go within 6 inches of the hopper bottom board. The shield may be perforated to permit observation of the dough ...
1910.263(e)(1)(iii) Special Industries,
Each mixer shall be equipped with an individual motor and control, and with a conveniently located manual switch to prevent the mixer from being ...
1910.263(g) Special Industries, Moulders
with the in-running rolls. Hand-fed moulders shall be provided ...
1910.263(e)(1)(v) Special Industries,
All mixers with power and manual dumping arrangements shall be equipped with safety devices which shall ...
1910.263(k) Special Industries, Biscuit and Cracker Equipment
and equal in effectiveness to guards on hand-fed brakes ...