• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

[F] 907.2.8.1 Manual Fire Alarm System

Building Code 2021 of Illinois > 9 Fire Protection and Life Safety Systems > 907 Fire Alarm and Detection Systems > 907.2 Where Required—New Buildings and Structures > 907.2.8 Group R-1 > 907.2.8.1 Manual Fire Alarm System
JUMP TO FULL CODE CHAPTER
A manual fire alarm system that activates the occupant notification system in accordance with Section 907.5 shall be installed in Group R- 1 occupancies.
Exceptions:
  1. A manual fire alarm system is not required in buildings not more than two stories in height where all individual sleeping units and contiguous attic and crawl spaces to those units are separated from each other and public or common areas by not less than 1-hour fire partitions and each individual sleeping unit has an exit directly to a public way, egress court or yard.
  2. Manual fire alarm boxes are not required throughout the building where all of the following conditions are met:
    2.1.  The building is equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2.
    2.2.  The notification appliances will activate upon sprinkler water flow.
    2.3.  Not fewer than one manual fire alarm box is installed at an approved location.

Related Code Sections


904.2.1 Alterations—Level 3, Manual Fire Alarm Systems
Where required by the International Building Code , a manual fire alarm system shall be provided throughout the work area . Alarm notification ...
Existing Building Code 2018 of Illinois > 9 Alterations—Level 3 > 904 Fire Protection > 904.2 Fire Alarm and Detection Systems > 904.2.1 Manual Fire Alarm Systems
904.2.1 Alterations—Level 3, Manual Fire Alarm Systems
Where required by the International Building Code , a manual fire alarm system shall be provided throughout the work area . Alarm notification ...
Existing Building Code 2021 of Illinois > 9 Alterations—Level 3 > 904 Fire Protection > 904.2 Fire Alarm and Detection Systems > 904.2.1 Manual Fire Alarm Systems
415.11.8 Special Detailed Requirements Based on Occupancy and Use, Manual Fire Alarm System
An approved manual fire alarm system shall be provided throughout buildings containing Group H-5. Activation of the alarm system shall initiate ...
Building Code 2018 of Illinois > 4 Special Detailed Requirements Based on Occupancy and Use > 415 Groups H-1, H-2, H-3, H-4 and H-5 > 415.11 Group H-5 > 415.11.8 Manual Fire Alarm System
415.11.9 Special Detailed Requirements Based on Occupancy and Use, Manual Fire Alarm System
An approved manual fire alarm system shall be provided throughout buildings containing Group H-5. Activation of the alarm system shall initiate ...
Building Code 2021 of Illinois > 4 Special Detailed Requirements Based on Occupancy and Use > 415 Groups H-1, H-2, H-3, H-4 and H-5 > 415.11 Group H-5 > 415.11.9 Manual Fire Alarm System
907.2.8.1 Fire Protection and Life Safety Systems, Manual Fire Alarm System
A manual fire alarm system that activates the occupant notification system in accordance with Section 907.5 shall be installed in Group R-1 ...
Building Code 2018 of Illinois > 9 Fire Protection and Life Safety Systems > 907 Fire Alarm and Detection Systems > 907.2 Where Required—New Buildings and Structures > 907.2.8 Group R-1 > 907.2.8.1 Manual Fire Alarm System
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING