• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

404.2 Manual Doors

Minnesota Accessibility Code 2015 > 4 Accessible Routes > 404 Doors and Doorways > 404.2 Manual Doors
JUMP TO FULL CODE CHAPTER
Manual doors and doorways, and manual gates, including ticket gates, shall comply with Section 404.2.
Exception: Doors, doorways, and gates designed to be operated only by security personnel shall not be required to comply with Sections 404.2.6, 404.2.7, and 404.2.8.

404.2.1 Double-Leaf Doors and Gates

At least one of the active leaves of doorways with two leaves shall comply with Sections 404.2.2 and 404.2.3.

404.2.2 Clear Width

ILLUSTRATION
Doorways shall have a clear opening width of 32 inches (815 mm) minimum. Clear opening width of doorways with swinging doors shall be measured between the face of door and stop, with the door open 90 degrees. Openings more than 24 inches (610 mm) in depth at doors and doorways without doors shall provide a clear opening width of 36 inches (915 mm) minimum. There shall be no projections into the clear opening width lower than 34 inches (865 mm) above the floor. Projections into the clear opening width between 34 inches (865 mm) and 80 inches (2030 mm) above the floor shall not exceed 4 inches (100 mm).
Exceptions:
  1. Door closers and door stops shall be permitted to be 78 inches (1980 mm) minimum above the floor.
  2. In alterations, a projection of 5/8 inch (16 mm) maximum into the required clear opening width shall be permitted for the latch side stop.

FIGURE 404.2.2
CLEAR WIDTH OF DOORWAYS

404.2.3 Maneuvering Clearances

Minimum maneuvering clearances at doors shall comply with Section 404.2.3 and shall include the full clear opening width of the doorway. Required door maneuvering clearances shall not include knee and toe clearance.

404.2.3.1 Floor Surface

Floor surface within the maneuvering clearances shall have a slope not steeper than 1:48 and shall comply with Section 302.

404.2.3.2 Swinging Doors

Swinging doors shall have maneuvering clearances complying with Table 404.2.3.2.

TABLE 404.2.3.2
MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS

TYPE OF USEMANEUVERING CLEARANCES AT MANUAL SWINGING DOORS
Approach DirectionDoor SidePerpendicular to DoorwayParallel to Doorway
(beyond latch unless noted)
From frontPull60 inches (1525 mm)18 inches (455 mm)
From frontPush48 inches (1220 mm)0 inches (0 mm)3
From hinge sidePull60 inches (1525 mm)36 inches (915 mm)
From hinge sidePull54 inches (1370 mm)42 inches (1065 mm)
From hinge sidePush42 inches (1065 mm)122 inches (560 mm)3 & 4
From latch sidePull48 inches (1220 mm)224 inches (610 mm)
From latch sidePush42 inches (1065 mm)224 inches (610 mm)
1. Add 6 inches (150 mm) if closer and latch provided.
2. Add 6 inches (150 mm) if closer provided.
3. Add 12 inches (305 mm) beyond latch if closer and latch provided.
4. Beyond hinge side.

FIGURE 404.2.3.2
MANEUVERING CLEARANCE AT MANUAL SWINGING DOORS

404.2.3.3 Sliding and Folding Doors

Sliding doors and folding doors shall have maneuvering clearances complying with Table 404.2.3.3.

TABLE 404.2.3.3
MANEUVERING CLEARANCES AT SLIDING AND FOLDING
DOORS

APPROACH
DIRECTION
MINIMUM MANEUVERING CLEARANCES
Perpendicular to
Doorway
Parallel to Doorway
(beyond stop or latch side unless noted)
From front48 inches (1220 mm)0 inches (0 mm)
From nonlatch side42 inches (1065 mm)22 inches (560 mm)1
From latch side42 inches (1065 mm)24 inches (610 mm)
1. Beyond pocket or hinge side.

FIGURE 404.2.3.3
MANEUVERING CLEARANCE AT SLIDING AND FOLDING DOORS

404.2.3.4 Doorways Without Doors

Doorways without doors that are less than 36 inches (915 mm) in width shall have maneuvering clearances complying with Table 404.2.3.4

TABLE 404.2.3.4
MANEUVERING CLEARANCES FOR
DOORWAYS WITHOUT DOORS

APPROACH DIRECTIONMINIMUM MANEUVERING
CLEARANCES
(Perpendicular to Doorway)
From front48 inches (1220 mm)
From side(1065 mm)

FIGURE 404.2.3.4
MANEUVERING CLEARANCE AT DOORWAYS WITHOUT DOORS

404.2.3.5 Recessed Doors

Where any obstruction within 18 inches (455 mm) of the latch side of a doorway projects more than 8 inches (205 mm) beyond the face of the door, measured perpendicular to the face of the door, maneuvering clearances for a forward approach shall be provided.

FIGURE 404.2.3.5
MANEUVERING CLEARANCE AT RECESSED DOORS

404.2.4 Thresholds

If provided, thresholds at doorways shall be 1/2 inch (13 mm) maximum in height. Raised thresholds and changes in level at doorways shall comply with Sections 302 and 303.
Exception: An existing or altered threshold shall be permitted to be 3/4 inch (19 mm) maximum in height provided that the threshold has a beveled edge on each side with a maximum slope of 1:2 for the height exceeding 1/4 inch (6.4 mm).

404.2.5 Two Doors in Series

Distance between two hinged or pivoted doors in series shall be 48 inches (1220 mm) minimum plus the width of any door swinging into the space. The space between the doors shall provide a turning space complying with Section 304.

FIGURE 404.2.5
TWO DOORS IN A SERIES

404.2.6 Door Hardware

ILLUSTRATION
Handles, pulls, latches, locks, and other operable parts on accessible doors shall have a shape that is easy to grasp with one hand and does not require tight grasping, pinching, or twisting of the wrist to operate. Operable parts of such hardware shall be 34 inches (865 mm) minimum and 48 inches (1220 mm) maximum above the floor. Where sliding doors are in the fully open position, operating hardware shall be exposed and usable from both sides.
Exception: Locks used only for security purposes and not used for normal operation shall not be required to comply with Section 404.2.6.

404.2.7 Closing Speed

404.2.7.1 Door Closers

Door closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to an open position of 12 degrees shall be 5 seconds minimum.

404.2.7.2 Spring Hinges

Door spring hinges shall be adjusted so that from an open position of 70 degrees, the door shall move to the closed position in 1.5 seconds minimum.

404.2.8 Door-Opening Force

Fire doors shall have the minimum opening force allowable by the appropriate administrative authority. The force for pushing or pulling open doors other than fire doors shall be as follows:
  1. Interior hinged door: 5.0 pounds (22.2 N) maximum.
  2. Sliding or folding door: 5.0 pounds (22.2 N) maximum.
These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door in a closed position.

404.2.9 Door Surface

ILLUSTRATION
Door surfaces within 10 inches (255 mm) of the floor, measured vertically, shall be a smooth surface on the push side extending the full width of the door. Parts creating horizontal or vertical joints in such surface shall be within 1/16 inch (1.6 mm) of the same plane as the other. Cavities created by added kick plates shall be capped.
Exceptions:
  1. Sliding doors shall not be required to comply with Section 404.2.9.
  2. Tempered glass doors without stiles and having a bottom rail or shoe with the top leading edge tapered at no less than 60 degrees from the horizontal shall not be required to comply with the 10-inch (255 mm) bottom rail height requirement.
  3. Doors that do not extend to within 10 inches (255 mm) of the floor shall not be required to comply with Section 404.2.9.

404.2.10 Vision Lites

ILLUSTRATION
Doors and sidelites adjacent to doors containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one panel on either the door or an adjacent sidelite 43 inches (1090 mm) maximum above the floor.
Exception: Vision lites with the lowest part more than 66 inches (1675 mm) above the floor shall not be required to comply with Section 404.2.10.

Related Code Sections


404.2 Accessible Routes, Manual Doors
Manual doors and doorways, and manual gates, including ticket gates, shall comply with Section 404.2. Exception: Doors, doorways, and gates ...
Minnesota Accessibility Code 2015 > 4 Accessible Routes > 404 Doors and Doorways > 404.2 Manual Doors
404.2.10 Accessible Routes, Vision Lites
Doors and sidelites adjacent to doors containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least ...
Minnesota Accessibility Code 2015 > 4 Accessible Routes > 404 Doors and Doorways > 404.2 Manual Doors > 404.2.10 Vision Lites
404.2.2 Accessible Routes, Clear Width
Doorways shall have a clear opening width of 32 inches (815 mm) minimum. Clear opening width of doorways with swinging doors shall be measured ...
Minnesota Accessibility Code 2015 > 4 Accessible Routes > 404 Doors and Doorways > 404.2 Manual Doors > 404.2.2 Clear Width
404.2.3 Accessible Routes, Maneuvering Clearances
with Table 404.2.3.2. TABLE 404.2.3.2 MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS TYPE OF USE MANEUVERING CLEARANCES AT MANUAL ...
Minnesota Accessibility Code 2015 > 4 Accessible Routes > 404 Doors and Doorways > 404.2 Manual Doors > 404.2.3 Maneuvering Clearances
404.2.4 Accessible Routes, Thresholds
If provided, thresholds at doorways shall be 1 / 2 inch (13 mm) maximum in height. Raised thresholds and changes in level at doorways shall comply ...
Minnesota Accessibility Code 2015 > 4 Accessible Routes > 404 Doors and Doorways > 404.2 Manual Doors > 404.2.4 Thresholds
Help Contact Us Privacy Terms
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE