803.5 Manual Dampers
JUMP TO FULL CODE CHAPTER
Manual dampers shall not be installed in connectors except in chimney connectors serving solid fuel-burning appliances.
Related Code Sections
803.5 Chimneys and Vents, Manual Dampers
Manual dampers shall not be installed in connectors except in chimney connectors serving solid fuel-burning appliances ...
Mechanical Code of the Texas Industrialized Housing and Buildings Program > 8 Chimneys and Vents > 803 Connectors > 803.5 Manual Dampers
503.13 Chimneys and Vents, Manually Operated Dampers
A manually operated damper shall not be placed in the vent connector for any appliance . Fixed baffles shall not be classified as manually operated ...
Fuel Gas Code of the Texas Industrialized Housing and Buildings Program > 5 Chimneys and Vents > 503 (IFGS) Venting of Appliances > 503.13 Manually Operated Dampers
G2427.13 Fuel Gas, (503.13) Manually Operated Dampers
A manually operated damper shall not be placed in the vent connector for any appliance . Fixed baffles shall not be classified as manually ...
Residential Code for one- and two-family dwellings of the Texas Industrialized Housing and Buildings Program > 24 Fuel Gas > G2427 (503) Venting of Appliances > G2427.13 (503.13) Manually Operated Dampers
701.2 Combustion Air, Dampered Openings
of the appliances served, so as to prevent operation of any appliance that draws combustion air from the room or space when any of the dampers are closed. Manual ...
Mechanical Code of the Texas Industrialized Housing and Buildings Program > 7 Combustion Air > 701 General > 701.2 Dampered Openings
M1802.2.1 Chimneys and Vents, Manually Operated
Manually operated dampers shall not be installed except in connectors or chimneys serving solid fuel-burning appliances ...
Residential Code for one- and two-family dwellings of the Texas Industrialized Housing and Buildings Program > 18 Chimneys and Vents > M1802 Vent Components > M1802.2 Vent Dampers > M1802.2.1 Manually Operated