• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1910.253(c)(5) Manifold Operating Procedures

OSHA 1910 General Industry > Q Welding, Cutting, and Brazing > 1910.253 Oxygen-Fuel Gas Welding and Cutting > 1910.253(c) Manifolding of Cylinders > 1910.253(c)(5) Manifold Operating Procedures
JUMP TO FULL CODE CHAPTER

1910.253(c)(5)(i)

Cylinder manifolds shall be installed under the supervision of someone familiar with the proper practices with reference to their construction and use.

1910.253(c)(5)(iii)

When acetylene cylinders are coupled, approved flash arresters shall be installed between each cylinder and the coupler block. For outdoor use only, and when the number of cylinders coupled does not exceed three, one flash arrester installed between the coupler block and regulator is acceptable.

1910.253(c)(5)(iv)

The aggregate capacity of fuel-gas cylinders connected to a portable manifold inside a building shall not exceed 3,000 cubic feet (84 m(3)) of gas.

1910.253(c)(5)(v)

Acetylene and liquefied fuel-gas cylinders shall be manifolded in a vertical position.

1910.253(c)(5)(vi)

The pressure in the gas cylinders connected to and discharged simultaneously through a common manifold shall be approximately equal.

1910.253(c)(5)(ii)

All manifolds and parts used in methods of manifolding shall be used only for the gas or gases for which they are approved.

Related Code Sections


1910.253(c)(5) Welding, Cutting, and Brazing, Manifold Operating Procedures
Cylinder manifolds shall be installed under the supervision of someone familiar with the proper practices with reference to their construction ...
OSHA 1910 General Industry > Q Welding, Cutting, and Brazing > 1910.253 Oxygen-Fuel Gas Welding and Cutting > 1910.253(c) Manifolding of Cylinders > 1910.253(c)(5) Manifold Operating Procedures
1910.253(c)(5)(vi) Welding, Cutting, and Brazing,
The pressure in the gas cylinders connected to and discharged simultaneously through a common manifold shall be approximately equal ...
OSHA 1910 General Industry > Q Welding, Cutting, and Brazing > 1910.253 Oxygen-Fuel Gas Welding and Cutting > 1910.253(c) Manifolding of Cylinders > 1910.253(c)(5) Manifold Operating Procedures > 1910.253(c)(5)(vi)
1910.253(b)(5) Welding, Cutting, and Brazing, Operating Procedures
the pressure through a suitable regulator attached to the cylinder valve or manifold ...
OSHA 1910 General Industry > Q Welding, Cutting, and Brazing > 1910.253 Oxygen-Fuel Gas Welding and Cutting > 1910.253(b) Cylinders and Containers > 1910.253(b)(5) Operating Procedures
1910.253(c) Welding, Cutting, and Brazing, Manifolding of Cylinders
Manifolds shall be approved either separately for each component part or as an assembled unit ...
OSHA 1910 General Industry > Q Welding, Cutting, and Brazing > 1910.253 Oxygen-Fuel Gas Welding and Cutting > 1910.253(c) Manifolding of Cylinders
1910.427(c) Commercial Diving Operations, Procedures
by each diver engaged in liveboating operations ...
OSHA 1910 General Industry > T Commercial Diving Operations > 1910.427 Liveboating > 1910.427(c) Procedures
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE