Where a clear floor or ground space is located in an alcove or otherwise confined on all or part of three sides, additional maneuvering clearance shall be provided in accordance with 305.7.1 and 305.7.2.
305.7.1 Forward Approach
Alcoves shall be 36 inches (915 mm)wide minimum where the depth exceeds 24 inches (610 mm).
Figure 305.7.1 Maneuvering Clearance in an Alcove, Forward Approach
For a forward approach, if the depth of the alcove is greater than 24 inches (610 mm), the clear floor or ground space within the alcove must be 36 inches (915 mm) wide minimum.
305.7.2 Parallel Approach
Alcoves shall be 60 inches (1525 mm) wide minimum where the depth exceeds 15 inches (380 mm).
Figure 305.7.2 Maneuvering Clearance in an Alcove, Parallel Approach
For a parallel approach, if the depth of the alcove is greater than 15 inches (380 mm), then the length of the clear floor or ground space within the alcove must be 60 inches (1525 mm) minimum.

Related Code Sections

305.7 Building Blocks, Maneuvering Clearance
Where a clear floor or ground space is located in an alcove or otherwise confined on all or part of three sides, additional maneuvering clearance ...
404.2.4 Accessible Routes, Maneuvering Clearances
Minimum maneuvering clearances at doors and gates shall comply with 404.2.4.  Maneuvering clearances shall extend the full width of the doorway ...
404.2.4.3 Accessible Routes, Recessed Doors and Gates
Maneuvering clearances for forward approach shall be provided when any obstruction within 18 inches (455 mm) of the latch side of a doorway projects ...
404.2.4.4 Accessible Routes, Floor or Ground Surface
Floor or ground surface within required maneuvering clearances shall comply with 302.  Changes in level are not permitted. EXCEPTIONS ...
405.7.5 Accessible Routes, Doorways
Where doorways are located adjacent to a ramp landing, maneuvering clearances required by 404.2.4 and 404.3.2 shall be permitted to overlap ...