• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

Section 110.4 Mandatory Requirements for Pool and Spa Systems and Equipment

California Energy Code 2019 > 2 All Occupancies — Mandatory Requirements for the Manufacture, Construction and Installation of Systems, Equipment and Building Components > 110.4 Mandatory Requirements for Pool and Spa Systems and Equipment
JUMP TO FULL CODE CHAPTER
  1. Certification by manufacturers. Any pool or spa heating system or equipment may be installed only if the manufacturer has certified that the system or equipment has all of the following:

    1. Efficiency. A thermal efficiency that complies with the Appliance Efficiency Regulations; and
    2. On-off switch. A readily accessible on-off switch, mounted on the outside of the heater that allows shutting off the heater without adjusting the thermostat setting; and
    3. Instructions. A permanent, easily readable and weatherproof plate or card that gives instruction for the energy efficient operation of the pool or spa heater and for the proper care of pool or spa water when a cover is used; and
    4. Electric resistance heating. No electric resistance heating.

      Exception 1 to Section 110.4(a)4: Listed package units with fully insulated enclosures, and with tight-fitting covers that are insulated to at least R-6.

      Exception 2 to Section 110.4(a)4: Pools or spas deriving at least 60 percent of the annual heating energy from site solar energy or recovered energy.

  2. Installation. Any pool or spa system or equipment shall be installed with all of the following:

    1. Piping. At least 36 inches of pipe shall be installed between the filter and the heater or dedicated suction and return lines, or built-in or built-up connections shall be installed to allow for the future addition of solar heating equipment;
    2. Covers. A cover for outdoor pools or outdoor spas that have a heat pump or gas heater; and
    3. Directional inlets and time switches for pools. If the system or equipment is for a pool:

      1. The pool shall have directional inlets that adequately mix the pool water; and
      2. A time switch or similar control mechanism shall be installed as part of a pool water circulation control system that will allow all pumps to be set or programmed to run only during off-peak electric demand period, and for the minimum time necessary to maintain the water in the condition required by applicable public health standards.

Related Code Sections


Section 110.4 All Occupancies—Mandatory Requirements for the Manufacture, Construction and Installation of Systems, Equipment and Building Components, Mandatory Requirements for Pool and Spa Systems and Equipment
(a) Certification by manufacturers. Any pool or spa heating system or equipment may be installed only if the manufacturer has certified ...
California Energy Code 2016 > 2 All Occupancies—Mandatory Requirements for the Manufacture, Construction and Installation of Systems, Equipment and Building Components > 110.4 Mandatory Requirements for Pool and Spa Systems and Equipment
Section 110.4 All Occupancies — Mandatory Requirements for the Manufacture, Construction and Installation of Systems, Equipment and Building Components, Mandatory Requirements for Pool and Spa Systems and Equipment
Certification by manufacturers. Any pool or spa heating system or equipment may be installed only if the manufacturer has certified that the system ...
California Energy Code 2019 > 2 All Occupancies — Mandatory Requirements for the Manufacture, Construction and Installation of Systems, Equipment and Building Components > 110.4 Mandatory Requirements for Pool and Spa Systems and Equipment
11B-242.4 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Spas
At least one accessible means of entry shall be provided for spas. Accessible means of entry shall comply with swimming pool lifts complying ...
California Building Code 2016 (Vol 1 & 2) > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-242 Swimming Pools, Wading Pools, and Spas > 11B-242.4 Spas
3120B.2.1 [DPH] Public Pools, Spa Pool
The pool user capacity of a spa pool shall be based on one pool user for every 10 square feet (0.929 m 2 ) of pool water surface area ...
California Building Code 2016 (Vol 1 & 2) > 31B [DPH] Public Pools > 3120B Required Signs > 3120B.2 Pool User Capacity Sign > 3120B.2.1 Spa Pool
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE