// CODE SNIPPET
84-132 Mandatory Front Building Walls
JUMP TO FULL CODE CHAPTER
Except as set forth in paragraphs (g) and (i) of this Section, where Appendices 2.1 or 3.1 show a requirement for a building in Zone A to be built to a mandatory front building wall line, any such building shall have a mandatory front building wall coincident with and constructed along such mandatory front building wall line, which shall rise without setback for a height above curb level, as specified in this Section, except that, at building entrances, openings below the second story ceiling in the mandatory front building walls will be permitted to provide access to courtyards:
(a) except as set forth in paragraph (d) of this Section, with respect to any 60-85 foot mandatory front building wall line shown in Appendix 2.1, a height of not less than 60 feet nor more than 85 feet;
(b) with respect to any 110-135 foot mandatory front building wall line shown in Appendix 2.1, a height of not less than 110 feet nor more than 135 feet. However, a setback of not more than 10 feet may be provided at a height of 85 feet or more above curb level ;
(c) on the portion of any zoning lot designated as a special height location in Appendix 2.2, a height of not less than the applicable amount set forth in paragraphs (a) or (b) of this Section and not more than the maximum height indicated in Appendix 2.2 or in paragraph (d)(1) of Section 84-135 (Limited height of buildings);
(d) with respect to any zoning lot south of West Thames Street, east of South End Avenue, north of Third Place and west of Battery Place, a height of not less than 18 feet nor more than 85 feet above curb level ;
(e) with respect to any 110-135 foot mandatory front building wall line shown in Appendix 3.1, a height of not less than 110 feet nor more than 135 feet;
(f) with respect to any 110-230 foot mandatory front building wall line shown in Appendix 3.1, a height of not less than 110 feet nor more than 230 feet, except that:
(1) the width of the mandatory front building wall in excess of a height of 135 feet shall not exceed 120 feet along any frontage;
(2) where the width of the mandatory front building wall line along street lines intersecting North End Avenue exceeds 100 feet, the mandatory front building wall in excess of a height of 135 feet shall not exceed a width of 75 feet along North End Avenue. However, the width of the mandatory front building wall along street lines intersecting North End Avenue may be reduced to not less than 100 feet in order to accommodate landscaping and other improvements within or adjacent to the public open space areas shown in Appendix 3.6;
(3) a setback of 10 feet at a height of 135 feet is required along all street frontages, except Park Place West; and
(4) a setback of not less than five feet and not more than 10 feet is required in other locations at a height of 135 feet, as shown in Appendix 3.1;
(g) with respect to any 150—250 foot mandatory front building wall line shown in Appendix 3.1, a height of not less than 150 feet nor more than 250 feet, except that the height may not exceed either 150 feet for more than 120 feet or 75 percent of the length of the site's western property line, whichever is less, and a setback of not less than five feet and not more than 10 feet is required at a height of 150 feet. Where Appendix 3.1 shows a requirement for a building to be built to a mandatory front building wall line along frontage on River Terrace, any such building may have a mandatory front building wall coincident with and constructed along a line set back one and one-half feet from the street line along River Terrace to accommodate landscaping treatment as required by the Battery Park City Authority;
(h) on the portion of any zoning lot designated as a special height location in Appendix 3.2, a height of not less than the applicable amount set forth in paragraphs (e), (f) or (g) of this Section and not more than the height shown in Appendix 3.2; and
(i) on the zoning lot south of First Place and west of Battery Place, the eastern mandatory front building wall may be located within 30 feet from the eastern mandatory front building wall line, and the southern mandatory front building wall may be reduced in width up to 30 feet along the southern mandatory front building wall line within 30 feet from the intersection with the eastern mandatory building wall line.
Subject to the provisions of Section 84-133 (Front wall recesses), the mandatory front building wall requirements set forth in this Section shall also apply to all buildings along all street lines within 50 feet of their intersection with any mandatory front building wall line. For the next 20 feet along the street line, the mandatory front building wall requirements are optional except that, for any building north of Vesey Street and Vesey Place, the mandatory front building wall requirements are optional for the next 25 feet. The height limit of 85 feet shall apply along street lines or to buildings not subject to the mandatory front building wall requirements.
Related Code Sections
§28-104.2.1.3.2 Administration, Mandatory Sanctions
training or continuing education courses, approved by the department, related to compliance with the building code and related laws and rules ...
NYC General Admin. Provisions 2008 > 1 Administration > 104 Construction Documents > §28-104.2 Application for Approval of Construction Documents > §28-104.2.1 Less Than Full Examination of Construction Documents > §28-104.2.1.3 Mandatory Program Requirements > §28-104.2.1.3.2 Mandatory Sanctions
**§28-104.2.1.3.2 Administration, Mandatory Sanctions
with the building code and related laws and rules and the zoning resolution. The professional shall submit satisfactory proof of the successful ...
NYC General Admin. Provisions 2014 > 1 Administration > 104 Construction Documents > *§28-104.2 Application for Approval of Construction Documents > **§28-104.2.1 Less Than Full Examination of Applications for Construction and Related Document Approval > §28-104.2.1.3 Mandatory Program Requirements > **§28-104.2.1.3.2 Mandatory Sanctions
**§28-104.2.1.3.2 Administration, Mandatory Sanctions
one or more training or continuing education courses, approved by the department, related to compliance with the New York city building code and related ...
NYC General Admin. Provisions 2022 > 1 Administration > 104 Construction Documents > *§28-104.2 Application for Approval of Construction Documents > **§28-104.2.1 Less Than Full Examination of Applications for Construction and Related Document Approval Based on Professional Certification > §28-104.2.1.3 Mandatory Program Requirements > **§28-104.2.1.3.2 Mandatory Sanctions
*§28-305.4.2 Maintenance of Buildings,
Owners of retaining walls with a height of ten feet or more and fronting a public right-of-way shall comply with the requirements of this section ...
NYC General Admin. Provisions 2008 > 3 Maintenance of Buildings > 305 Retaining Walls > *§28-305.4 Maintenance, Inspection and Repair of Retaining Walls > *§28-305.4.2
§28-401.19.3 Licensing and Registration of Businesses, Trades and Occupations Engaged in Building Work, Mandatory Suspension or Revocation
of the New York city building code, or of failing to insure that workers have certificates of fitness required pursuant to this code or applicable rule ...
NYC General Admin. Provisions 2022 > 4 Licensing and Registration of Businesses, Trades and Occupations Engaged in Building Work > 401 General > §28-401.19 Suspension or Revocation of License or Certificate of Competence > §28-401.19.3 Mandatory Suspension or Revocation