• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

82-10 Mandatory District Improvements

NYC Zoning Resolution > VIII Special Purpose Districts > 2 - Special Lincoln Square District (L) > 82-10 Mandatory District Improvements
JUMP TO FULL CODE CHAPTER

The provisions of this Section specify mandatory or optional physical improvements to be provided in connection with developments on certain zoning lots located within the Special District.

82-11 Special Provisions for Optional Arcades

Any development located on a zoning lot with a lot line which coincides with either of the following street lines - the east side of Broadway between West 61st and West 65th Streets or the east side of Columbus Avenue between West 65th and West 66th Streets - may contain an arcade as defined in Section 12-10, except that:

(a)        the arcade shall extend the full length of the zoning lot along the street lines described above; however, the required arcade along the east side of Columbus Avenue may be terminated at a point 40 feet south of West 66th Street;

(b)        the exterior face of building columns shall lie along the street lines described above;

(c)        the minimum depth of the arcade shall be 15 feet (measured perpendicular to the exterior face of the building columns located on the street line) and the minimum height of the arcade along the center line of its longitudinal axis shall not be less than 20 feet;

(d)        the arcade shall contain no permanent obstruction within the area delineated by the minimum width and height requirements of this Section except for the following:

(1)        unenclosed cafes, provided that there is at least a six foot wide unobstructed pedestrian way adjacent to the street wall. In no event may such cafes be enclosed at any time; and

(2)        structural columns not exceeding two feet by three feet provided that the longer dimension of such columns is parallel to the street line, that such columns are spaced at a minimum of 17 feet on center, and that the space between such columns and the face of the street wall is at least 13 feet wide. No other columns shall project beyond the face of the street wall ;

(e)        no signs may be affixed to any part of the arcade or building columns except on a parallel to the street wall projecting no more than 18 inches therefrom parallel to the street line along which the arcade lies; and

(f)        the arcade shall be illuminated only by incandescent lighting to a standard of average eight foot-candle intensity with a minimum five foot-candle intensity at any point within the arcade.

82-12 Mandatory Off-Street Relocation of a Subway Stair

Where a development is constructed on a zoning lot that fronts on a sidewalk containing a stairway entrance into the West 59th Street (Columbus Circle) or the West 66th Street subway station and such zoning lot contains 5,000 square feet or more of lot area, the existing entrance shall be relocated from the street onto the zoning lot in accordance with the provisions of Sections 37-41 (Standards for Location, Design and Hours of Public Accessibility) and 37-42 (Administrative Procedure for a Subway Stair Relocation or Renovation).

82-13 Special Provisions for a Transit Easement

Any development located on the east side of Broadway between West 66th Street and West 67th Street shall provide an easement on the zoning lot for public access to the subway mezzanine or station when required by the New York City Transit Authority (TA) in accordance with the procedure set forth in Section 95-04 (Certification of Transit Easement Volume) and hereby made applicable.

Related Code Sections


**§28-104.2.1.3.2 Administration, Mandatory Sanctions
The commissioner shall, after the opportunity for a hearing before the office of administrative trials and hearings in accordance ...
NYC General Admin. Provisions 2014 > 1 Administration > 104 Construction Documents > *§28-104.2 Application for Approval of Construction Documents > **§28-104.2.1 Less Than Full Examination of Applications for Construction and Related Document Approval > §28-104.2.1.3 Mandatory Program Requirements > **§28-104.2.1.3.2 Mandatory Sanctions
§28-104.2.1.3.2 Administration, Mandatory Sanctions
The commissioner shall, after the opportunity for a hearing before the office of administrative trials and hearings in accordance with department ...
NYC General Admin. Provisions 2008 > 1 Administration > 104 Construction Documents > §28-104.2 Application for Approval of Construction Documents > §28-104.2.1 Less Than Full Examination of Construction Documents > §28-104.2.1.3 Mandatory Program Requirements > §28-104.2.1.3.2 Mandatory Sanctions
Section G303 Flood-Resistant Construction, Site Improvement
Development or land disturbing activity is prohibited in floodways unless it has been demonstrated through hydrologic and hydraulic analyses performed ...
NYC Building Code 2014 > G Flood-Resistant Construction > G303 Site Improvement
Section G303 Flood-Resistant Construction, Site Improvement
Development or land disturbing activity is prohibited in floodways unless it has been demonstrated through hydrologic and hydraulic analyses performed ...
NYC Building Code 2008 > G Flood-Resistant Construction > G303 Site Improvement
§28-108.3 Administration, Improvement of Streets
The commissioner shall insure that streets are suitably improved in accordance with the standards and specifications of the department ...
NYC General Admin. Provisions 2014 > 1 Administration > 108 Pavement Plan > §28-108.3 Improvement of Streets
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE